Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

 

 

 

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

 

4. Pilot lights but contin-

sensing rod.

connections underneath pilot assembly are tight. Verify

 

ues to spark, and main

 

flame sense or igniter wires are not grounding out to metal

 

burner will not ignite.

 

chassis, pilot burner, pilot enclosure or screen if present, or

 

(If the pilot continues

 

any other metal object.

 

to spark after the

 

 

 

B. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

 

pilot flame has been lit,

 

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

 

flame rectification has

 

 

sensing rod should glow shortly after ignition. With a multi-

 

not occurred.)

 

 

 

meter, verify that current in series between module and

 

 

 

 

 

 

sense lead is at least 0.14 microamps. Verify correct pilot

 

 

 

orifice is installed and gas inlet is set to pressure specifi-

 

 

cations. Polish flame sensing rod with fine steel wool to

 

 

remove any contaminants that may have accumulated on

 

 

 

flame sensing rod.

 

 

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

 

pliance. Verify that wire harness is firmly connected to the

 

 

 

module.

 

 

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing rod

 

 

nated flame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

 

flame sensing rod to white sensor wire. Polish flame sens-

 

 

ing rod with fine steel wool to remove any contaminants

 

 

that may have accumulated on flame sensing rod. Verify

 

 

 

continuity with a multi-meter with ohms set at lowest range.

 

 

 

Replace pilot if any damage is detected.

 

 

 

 

 

58

Heat & Glo • ESC-42ST2146-900 Rev. o • 5/12

Image 58
Contents What to do if you smell gas Model ESC-42STDo Discardnot Congratulations Homeowner Reference InformationTable of Contents User GuideTroubleshooting Appliance SetupReference Materials Limited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Control Decorative Doors and FrontsNine Hour Safety Shutdown Feature IPI Battery Tray/Battery InstallationModule Reset Control Module OperationLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitGlass Cleaning Exterior of Installed Glass Only Maintenance and ServiceMaintenance Tasks-Homeowner Doors, Surrounds, FrontsGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass LogsLight Bulb Maintenance Frequency As neededGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesBoard not Shown Attached to Constructing the Appliance Chase Minimum Framing DimensionsClearances Mantel and Wall Projections MIN MAX NON-COMBUSTIBLE Material Fireplace OpeningHearth Extension Combustible MaterialTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Inches U.S.AVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsVent Diagrams Two Elbows Top Vent Horizontal TerminationTop Vent Horizontal Termination One Elbow H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Ht Max Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Appliance Package IdentificationAssemble Vent Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Secure the Vent Sections10 Rotate Seams for Disassembly Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Horizontal Termination Cap Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Gas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Service and Repair Junction Box Installation Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationIPI Wiring Diagram Finishing Facing Material DoorsElevated Hearth Systems Model Description Elevated Appliance DimensionESC-42ST Appliance Setup TABInstalling the Optional Heat-ZoneGas Kit Clean the ApplianceAccessories Remove the Shipping MaterialsAccent Lights Install Light BulbsEmber Lights ScrewsFlange Install RefractoryNotch Outer Firebox Flange Refractory ClipsInstall Teco-Sil Glass Ember Rock Mystic Ember PlacementLOG Placement Instructions Grate BAR Grate Tine 4 Ember/Mineral Wool Placement Install Outer Refractory PanelsAir Shutter Setting Install MeshInstall Trim and/or Surround Air Shutter SettingsSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAPRF6M RF12M Optional Wire Harness Description Part NumberRefractory Assembly Log Set Assembly Service PartsAt Depot Service Parts ListDescription Comments Part Number Pre SN Stocked#28 IPI Valve Assembly Post SN Contact Information