Heat & Glo LifeStyle ESC-42ST Service Parts List, At Depot, Description Comments Part Number

Page 65

C. Service Parts List

 

 

ESC-42ST

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

 

 

 

parts for your appliance please provide model number and serial number. All parts listed

 

 

Stocked

in this manual may be ordered from an authorized dealer.

 

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

 

Log Set Assembly

 

LOGS-ESC42ST

 

Y

1

Log 1

 

SRV2146-701

 

 

2

Log 2

 

SRV2146-702

 

 

3

Log 3

 

SRV2146-703

 

 

4

Log 4

 

SRV2146-704

 

 

5

Log 5

 

SRV2146-705

 

 

6

Log 6

 

SRV2146-706

 

 

7

Log 7

 

SRV2146-707

 

 

8

Log 8

 

SRV2146-708

 

 

9

Light Box Mesh Assembly

Qty 2 req

2146-016

 

 

10

Non-combustible Board

Qty 2 req

2146-051

 

 

11

Finishing Strips

Qty 6 req

2146-129

 

 

12

Glass Door Assembly

Qty 2 req

GLA-ESC42ST

 

Y

13

Mesh Assembly

Qty 2 req

2146-031

 

Y

14

Log Grate

 

2146-015

 

 

15

Light Assembly Accent

35"

2146-013

 

 

16

Light Assembly Accent

17"

2146-014

 

 

17

Light Assembly, Ember

 

2146-404

 

 

18

Burner

 

2146-007

 

Y

19

Refractory Support

Qty 2 req

2146-152

 

 

20

Light Wire Connectors

 

2146-407

 

 

21

Refractory Panel - Outside Left

Qty 2 req

SRV2146-315

 

 

22

Refractory Panel- Inside Side

Qty 2 req

SRV2146-311

 

 

23

Refractory Panel- Outside Right

Qty 2 req

SRV2146-314

 

 

24

Refractory Panel-Outside Bottom

Qty 2 req

SRV2146-316

 

 

25

Refractory Panel-Inside Front

Qty 2 req

SRV2146-312

 

 

26

Refractory Panel-Inside Middle

Qty 2 req

SRV2146-313

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access Plate, Junction Box

 

2146-169

 

 

 

Fiberglass Rope

 

060-455

 

 

 

Flue Restrictor

 

2146-158

 

 

 

Mineral Wool

 

050-721

 

 

 

Teco-Sil, 5lb. Bag White Ember Bed Rock

 

700-790

 

 

 

Touch Up Paint

 

TUP-GBK-12

 

 

 

Twig Center

 

SRV582-707

 

 

 

Vermiculite Embers

 

MYSTIC-EMBERS

 

Additional service part numbers appear on following page.

Heat & Glo • ESC-42ST2146-900 Rev. o • 5/12

65

Image 65
Contents Do Discardnot Model ESC-42STWhat to do if you smell gas Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting Limited Lifetime Warranty Warranty Conditions Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Control Fixed Glass AssemblyClear Space Decorative Doors and FrontsModule Reset IPI Battery Tray/Battery InstallationNine Hour Safety Shutdown Feature Control Module OperationFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Exterior of Installed Glass Only Doors, Surrounds, FrontsGlass Cleaning Exterior and Interior of Installed Glass Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsFrequency As needed Light Bulb MaintenanceTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Board not Shown Attached to Framing and ClearancesSelecting Appliance Location Clearances Minimum Framing DimensionsConstructing the Appliance Chase MIN MAX NON-COMBUSTIBLE Material Fireplace Opening Mantel and Wall ProjectionsCombustible Material Hearth ExtensionVent Termination Minimum Clearances Termination LocationsInches U.S.A Covered Alcove ApplicationsApproved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One Elbow Top Vent Horizontal TerminationTwo Elbows H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Ht Max Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Non-Combustible Wall PenetrationPipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationAppliance Package Identification Securing and Leveling the ApplianceAttach Vent to the Firebox Assembly Installing Vent PipeAssemble Vent Sections Assemble Pipe SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections 10 Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Horizontal Termination Cap Fuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsElectrical Service and Repair Junction Box Installation Electrical InformationIPI Wiring Diagram Finishing Doors Facing MaterialESC-42ST Model Description Elevated Appliance DimensionElevated Hearth Systems TAB Appliance SetupAccessories Clean the ApplianceInstalling the Optional Heat-ZoneGas Kit Remove the Shipping MaterialsEmber Lights Install Light BulbsAccent Lights ScrewsNotch Install RefractoryFlange Outer Firebox Flange Refractory ClipsMystic Ember Placement Install Teco-Sil Glass Ember RockLOG Placement Instructions Grate Tine Grate BAR 4 Install Outer Refractory Panels Ember/Mineral Wool PlacementInstall Trim and/or Surround Install MeshAir Shutter Setting Air Shutter SettingsIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Reference Materials Appliance Dimension DiagramDVP-AS2 Vent Components DiagramsDVP-TRAP DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2RF6M RF12M Description Part Number Optional Wire HarnessService Parts Refractory Assembly Log Set AssemblyDescription Comments Part Number Service Parts ListAt Depot Stocked Pre SN#28 IPI Valve Assembly Post SN Contact Information