FireplaceXtrordinair 36CF Vent Requirements, Approved Vent, Altitude Considerations

Page 19

Installation (for qualified installers only)

19

Vent Requirements

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separate vent system.

In addition to the requirements listed here, follow the requirements provided with the vent.

A firestop is required whenever the vent penetrates a floor or ceiling (or passes through horizontal framing members). A thimble is required whenever the vent passes through a wall (or horizontal framing members).

Venting installation instructions may be found at www.duravent.com. Keep the vent instructions, along with this manual, with the appliance for future reference.

Approved Vent

This fireplace may only use the following vent components (8-5/8” / 6” external diameter co- axial vent). These parts are available from Travis Dealers.

 

 

Simpson Part #

Travis Part #

6” Length

68GSS-06

98900024

12” Length

68GSS-12

98900023

24” Length

68GSS-24

98900022

36” Length

68GSS-36

98900021

48” Length

68GSS-48

98900020

4” to 8” Adjustable Length (Slip Connector)

68GSS-12A

98900025

45°

Elbow

68GSS-L45

98900026

90°

Elbow

68GSS-L90

98900027

Wall Thimble

68G-SS-WT

98900030

Fire Stop

68G-SS-FS

98900029

Elbow Strap

68G-SS-ES

98900028

Wall Strap

68G-SS-WS

98900031

Adjustable Roof Flashing (0/12 to 6/12)

68G-SS-F

98900035

Adjustable Roof Flashing (7/12 to 12/12)

68G-SS-SF

98900036

Storm Collar

68G-SS-SC

98900032

Vinyl Siding Stand-off

68GSS-VSS

98900037

Horizontal Termination

68G-SS-HC

98900033

Vertical Termination

68G-SS-VC

98900034

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 6,000 feet. In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock in place.

Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired.

High temperature sealant is recommended at the appliance starter section connection (use high-temperature silicone or Mill-Pac®).

If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections.

Horizontal sections require a 1/4" rise every 12" of travel

Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)

© Travis Industries

4090102

100-01212_000

Image 19
Contents CF ST/Pier Gas Fireplace Overview Listing Details 2IntroductionTable of Contents Safety Warnings Safety PrecautionsSafety Precautions Dimensions Features and SpecificationsInstallation Options SpecificationsPacking List Recommended Installation ProcedureAdditional Items Required Massachusetts Requirements Preparing the Fireplace Stand-offs Clearances Fireplace Placement RequirementsRaised Fireplaces Back Minimum Framing 36 CF ST See ThroughFront Framing Dimensions 36 CF PierAttaching Stand-Offs to Framing Required Electrical Connection Do not route the wires over the top Fireplace Battery Pack / Learn Switch InstallationInstallation Warning Remote Synchronization Steps for Installing the Battery Box and Learn SwitchBattery Installation Synchronizing the Remote Remote SynchronizationGas Line Connection Gas Line RequirementsGas Inlet Pressure Altitude Considerations Vent InstallationVent Requirements Approved VentVent Location Vent ClearancesExhaust Restrictor Adjustment Approved Vent Configurations0feet Max 5feet Approved Vent Configuration Rear Vent, Horz. Term 45 ElbowFeet max 0feet 5feet 10feet 15feet 20max Max 0feet 5feet 10feet 15feet 20max Feet Max Feet max 0feet 5feet 10feet 15feet 20max Installation for qualified installers only 0feet 5feet Feet max 10feet 15feet 40feet max Feet 5feet 10feet 15feet 20max Max 40feet max Feet 5feet 10feet 15feet Termination Requirements Flush Hearth Hearth RequirementsHearth Requirements Recessed Hearth Facing Requirements Non-Combustible Facing See Through Mantel RequirementsSteps for Finalizing the Installation Finalizing the Installation for qualified installers onlyAir Shutter Adjustment Finalizing the Installation for qualified installers onlyGlass Frame Glass Trim Glass Frame Removal and InstallationEmber Placement Log Set InstallationRock Wool Placement Log Installation Top 2 logs last 2 logs Picture from opposite side Picture from end Pier only LP Conversion Instructions Finalizing the Installation for qualified installers only Orifice Table Rate Screws Andiron Installation Power Heat Duct Installation48Index