PB Heat Gas/Oil Boilers manual Standard and Optional Sections for Knockdown Boilers

Page 10

PREINSTALLATION

Table 1.3: Standard and Optional Sections for Knockdown Boilers

 

 

 

50 psig MAWP

 

 

80 psig MAWP

 

Sections

 

 

 

 

 

 

 

 

 

 

Standard

w/Inspection Tappings

No Inspection Tappings

w/Inspection Tappings

 

 

No Inspection Tappings

 

 

 

 

 

 

 

 

 

 

Front

Part #/UPC

LC-1001

86000

LC-1013

86010

LC-1001-2

86002

LC-1013-2

86012

Plain Interm.

Part #/UPC

LC-1000

86004

LC-1014

86014

LC-1000-2

86006

LC-1014-1

86015

Top Flue Interm.

Part #/UPC

LCE-1056

86100

LCE-1064

86110

LCE-1056-1

86111

LCE-1064-1

86112

LWCO Interm.

Part #/UPC

LC-1000-1

86005

LC-1014-2

86092

LC-1000-3

86007

LC-1014-3

86093

3" Tap. Interm.

Part #/UPC

LC-1003

86008

LC-1015

86016

LC-1003-2

86009

LC-1015-1

86017

Closed Back

Part #/UPC

LC-1007

86022

LC-1016

86018

LC-1007-2

86024

LC-1016-2

86020

Coil Back

Part #/UPC

LC-1002

86036

LC-1017

86026

LC-1002-2

86038

LC-1017-2

86028

 

 

 

 

 

 

 

 

 

 

Table 1.4: Standard and Optional Jacket Cartons, Front/Back Panels

Standard 50

86030

psig MAWP

 

 

 

30 psig MAWP

86059

 

 

80 psig MAWP

86058

 

 

Note: 80 psig MAWP not available in Canada.

Table 1.5: Standard and Optional Jacket Cartons, Top/Side Panels

 

Standard

With Inspection

Jacket Label

(No Inspection

Tappings

 

Tappings)

 

 

 

 

 

A

86031

86101

 

 

 

B

86032

86102

 

 

 

C

86033

86103

 

 

 

D

86034

86104

 

 

 

E

86094

86097

 

 

 

Note: Boilers with inspection tappings in front and back sections only use standard cartons.

Table 1.6A: Burner Mounting Plates

 

 

 

 

 

 

Boiler Model

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

LC-04

LC-05R

LC-05

LC-06

LC-07

LC-08

LC-09

LC-10

LC-11

LC-12

 

 

 

 

 

 

 

 

 

 

 

 

 

CF-800

86070*

86070*

 

 

 

 

 

 

 

 

Beckett

CF-1400

 

 

86069*

86069*

86069*

 

 

 

 

 

 

CF-2300

 

 

 

 

 

86074*

86074*

86074*

86074*

86074*

 

301CRD

86070*

86070*

 

 

 

 

 

 

 

 

Carlin

702CRD

 

 

86069*

86069*

86069*

86069*

 

 

 

 

 

801CRD

 

 

 

 

 

 

86073

86073

86073

86073

 

S4.2

86070*

86070*

 

 

 

 

 

 

 

 

Gordon

R6.2

 

 

86078

 

 

 

 

 

 

 

R6.3

 

 

 

86078

 

 

 

 

 

 

Piatt

R8.1

 

 

 

 

86079

86079

 

 

 

 

 

R8.2

 

 

 

 

 

 

86079

86079

86079

 

 

R8.3

 

 

 

 

 

 

 

 

 

86079

 

C1

86071

86071

86071

86071

86071

 

 

 

 

 

Power

C2

 

 

 

 

 

86076

86076

86076

86076

86076

J15A

86072

86072

 

 

 

 

 

 

 

 

Flame

 

 

 

 

 

 

 

 

J30A

 

 

86072

86072

86072

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J50A

 

 

 

 

 

86077

86077

86077

86077

 

Webster

JB1

86071

86071

86071

86071

86071

86075

86075

86075

86075

86075

* Standard Burner Mounting Plate

8

Image 10
Contents Series LC/LCE Table of Contents Using this Manual Special Attention BoxesPreinstallation Accessibility ClearancesCombustion and Ventilation AIR Clearance from Combustible ConstructionChimney or Vent Boiler Setting Foundation LayoutVerify Components Installation SurveyPlanning the Layout Foundation Lengths2A Series LC Shipping List Lwco2B Series LCE Shipping List Interm BackStandard and Optional Jacket Cartons, Top/Side Panels Standard and Optional Sections for Knockdown BoilersStandard and Optional Jacket Cartons, Front/Back Panels 6A Burner Mounting PlatesTrim Cartons 6B Burner Mounting PlatesControl Cartons Assembled Block Boiler Place the BoilerPackaged Boiler Knockdown BoilerApply Silcone Sealant Place the Boiler Series LC Boiler Assembly Right Side View Series LCE Boiler Assembly Right Side View Torque Specification/Procedure ModelLC/LCE Boiler Section Assembly Sequence Hydrostatic Test the Boiler Install Coils or PlatesTankless Coil Ratings Apply Cleanout Cover Plates Install Flue CollarInstall Flue Baffles Install Chamber LinerPipe the Boiler LOW System TemperatureLow Return Temperature Piping, General Preparation@ 20F Output Rise Return ConnectionsSize Header Constant Low Temperature Variable Low TemperatureChilled Water Systems Multiple Boiler InstallationsHigh Flow Rate Piping Piping for Variable Low Temperature Systems, Single Boiler Pipe the Boiler Pipe the Boiler Assemble the Jacket Jacket Assembly Venting Install the BurnerInstall Burner Mounting Plate Burner ApplicationBeckett Carlin Gordon Power Webster Inches Piatt Chamber Burner Front Plate Extension Past Jacket InchesConnect Fuel Piping Install Fuel OIL PipingInstall GAS Supply Piping GeneralPipe Pipe LengthSpecific Gravity Multiply Capacity by Install Drain Valve Install Controls and TrimInstall Safety Relief Valve Install LOW Water CutoffsInstall Control Wiring Connect Supply WiringPipe Tankless Heaters if Used Control and Pipe Tapping Locations Suggested Piping Single Tankless Coil Installation Fill the Boiler Starting the BoilerCheck the Piping RUN Burner CHECK-OUTTypical Combustion Chamber Pressure and Boiler Draft Loss Check Boiler ControlsModel Combustion Chamber Pressure Boiler Draft Loss Maintenance Placing Boiler in Operation Maintenance AnnualTo Shut Down the Boiler Monthly Maintenance Daily MaintenanceBoiler Ratings & Dimensions Series LC/LCE Boiler RatingsSeries LC Dimensional Diagram Series LC/LCE Boiler Dimensions Series LC/LCE Boiler DimensionsRepair Parts Series LC Boiler Assembly1A Series LC Repair Parts Description Part Selection Information Stock Code1B Series LC Repair Parts Series LCE Boiler Assembly 2A Series LCE Repair Parts 2B Series LCE Repair Parts Page Page Series LC/LCE