BOILER RATINGS & DIMENSIONS
11. BOILER RATINGS & DIMENSIONS
Table 11.1: Series LC/LCE Boiler Ratings
SERIES LC/LCE BOILER RATINGS
| Gross |
| I=B=R Burner Capacity |
| I=B=R Net Ratings |
| Combustion Efficiency | ||||
Boiler | I=B=R |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
Model | Output | Boiler | Oil | Gas | Steam |
| Steam |
| Water |
|
|
Number | Mbh | H.P. | GPH | MBH | Sq. Ft. |
| MBH |
| MBH | Oil | Gas |
547 | 16.3 | 4.75 | 686 | 1708 |
| 410 |
| 476 | 83.7 | 81.2 | |
| 649 | 19.4 | 5.60 | 808 | 2029 |
| 487 |
| 564 | 83.7 | 81.2 |
707 | 21.1 | 6.10 | 881 | 2208 |
| 530 |
| 615 | 83.7 | 81.2 | |
868 | 25.7 | 7.50 | 1077 | 2713 |
| 651 |
| 755 | 83.7 | 81.1 | |
1029 | 30.7 | 8.80 | 1273 | 3217 |
| 772 |
| 895 | 83.6 | 81.1 | |
1189 | 35.5 | 10.20 | 1469 | 3717 |
| 892 |
| 1034 | 83.6 | 81.1 | |
1350 | 40.3 | 11.60 | 1664 | 4250 |
| 1020 |
| 1174 | 83.6 | 81.1 | |
1511 | 45.1 | 12.80 | 1860 | 4804 |
| 1153 |
| 1314 | 83.6 | 81.1 | |
1672 | 49.9 | 14.20 | 2056 | 5367 |
| 1288 |
| 1454 | 83.6 | 81.1 | |
1832 | 54.7 | 15.60 | 2252 | 5917 |
| 1420 |
| 1593 | 83.6 | 81.1 | |
1966 | 58.7 | 17.00 | 2464 | 6358 |
| 1526 |
| 1710 | 83.5 | 81.0 | |
2125 | 63.5 | 18.40 | 2657 | 6875 |
| 1650 |
| 1848 | 83.5 | 81.0 | |
2284 | 68.2 | 19.80 | 2850 | 7388 |
| 1773 |
| 1986 | 83.5 | 81.0 | |
2444 | 73.0 | 21.00 | 3043 | 7908 |
| 1898 |
| 2125 | 83.5 | 81.0 | |
2603 | 77.8 | 22.50 | 3236 | 8421 |
| 2021 |
| 2263 | 83.5 | 81.0 | |
2763 | 82.5 | 24.00 | 3429 | 8938 |
| 2145 |
| 2403 | 83.5 | 81.0 | |
2922 | 87.3 | 25.00 | 3622 | 9454 |
| 2269 |
| 2541 | 83.5 | 81.0 | |
3082 | 92.1 | 26.50 | 3815 | 9971 |
| 2393 |
| 2680 | 83.5 | 81.0 | |
3256 | 97.3 | 28.00 | 4027 | 10533 |
| 2528 |
| 2831 | 83.6 | 81.1 | |
3430 | 102.5 | 29.50 | 4239 | 11096 |
| 2663 |
| 2983 | 83.6 | 81.1 | |
3604 | 107.7 | 31.00 | 4451 | 11658 |
| 2798 |
| 3134 | 83.7 | 81.2 | |
3777 | 112.8 | 32.50 | 4663 | 12217 |
| 2932 |
| 3284 | 83.7 | 81.2 | |
|
|
|
|
|
|
|
|
|
|
|
|
1Burner input based on No. 2 fuel oil with a heating value of 140,000 Btu per gallon.
2Net I=B=R water ratings based on an allowance of 1.15.
3Net I=B=R steam ratings based on an allowance for
4Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
5Combustion efficiency determined in accordance with The Hydronics Institute’s Testing and Rating Standard for Heating Boilers.
Figure 11.1: Tankless Coil Pressure Drops
42