PB Heat Gas/Oil Boilers manual Series LC/LCE Boiler Dimensions

Page 46

44

Table 11.2: Series LC/LCE Boiler Dimensions

SERIES LC/LCE BOILER DIMENSIONS

 

 

Jacket

 

Supply Piping

Return Piping

Riser Tapping Locations*

 

Vent Location

Vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

 

 

 

 

 

 

 

 

 

 

Intermediate

Burner

 

 

 

 

Model

Width

Length

Height

 

 

Recom.

 

 

Recom.

Ends

Section Tapping

Center

 

 

 

Minimum

Number

“A”

“B”

“C”

Number

Size

Header

Number

Size

Header

“G”

“G1”

“G2”

Line

“D”

“E”

Diameter

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LC-04

37″

25¹⁵⁄₁₆″

63″

1

2¹⁄₂″

2¹⁄₂″

1

2¹⁄₂″

2¹⁄₂″

16¹⁄₂″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

9″

3′

LC-05R

37″

31″

63″

1

2¹⁄₂″

2¹⁄₂″

1

2¹⁄₂″

2¹⁄₂″

21⁹⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

9″

3′

LC-05

37″

31″

63″

1

2¹⁄₂″

2¹⁄₂″

1

2¹⁄₂″

2¹⁄₂″

21⁹⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

9″

3′

LC-06

37″

36¹⁄₁₆″

63″

1

3″

3″

1

3″

3″

26⁵⁄₈″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

10″

3′

LC-07

37″

41¹⁄₈″

63″

1

3″

3″

1

3″

3″

31¹¹⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

10″

3′

LC-08

37″

46⁵⁄₁₆″

63″

2

3″

3″

2

3″

3″

36¹³⁄₁₆″

15¹³⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

10″

3′

LC-09

37″

51³⁄₈″

63″

2

3″

3″

2

3″

3″

41⁷⁄₈″

20¹⁵⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

12″

3′

LC-10

37″

56⁷⁄₁₆″

63″

2

3″

4″

2

3″

4″

46¹⁵⁄₁₆″

20¹⁵⁄₁₆″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

12″

3′

LC-11

37″

61¹⁄₂″

63″

2

3″

4″

2

3″

4″

52″

26″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

12″

3′

LC-12

37″

66⁹⁄₁₆″

63″

2

3″

4″

2

3″

4″

57¹⁄₈″

26″

18¹⁄₂″

18¹⁄₄″

54¹⁄₈″

12″

3′

LCE-13

37″

71³⁄₄″

63″

2

4″

4″

2

3″

4″

62³⁄₁₆″

36³⁄₁₆″

18¹⁄₂″

16″

20¹⁄₂″

14″

3′

LCE-14

37″

76¹³⁄₁₆″

63″

2

4″

4″

2

3″

4″

67¹⁄₄″

41¹⁄₄″

18¹⁄₂″

16″

20¹⁄₂″

14″

3′

LCE-15

37″

81⁷⁄₈″

63″

2

4″

4″

2

3″

4″

72⁵⁄₁₆″

46³⁄₈″

18¹⁄₂″

16″

20¹⁄₂″

14″

3′

LCE-16

37″

86¹⁵⁄₁₆″

63″

2

4″

4″

2

3″

4″

77⁷⁄₁₆″

51⁷⁄₁₆″

18¹⁄₂″

16″

20¹⁄₂″

14″

3′

LCE-17

37″

92¹⁄₈″

63″

2

4″

5″

2

3″

5″

82¹⁄₂″

41¹⁄₄″

18¹⁄₂″

16″

20¹⁄₂″

14″

3′

LCE-18

37″

97³⁄₁₆″

63″

2

4″

5″

2

3″

5″

87⁹⁄₁₆″

41¹⁄₄″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-19

37″

102¹⁄₄″

63″

2

4″

5″

2

3″

5″

92⁵⁄₈″

41¹⁄₄″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-20

37″

107⁷⁄₁₆″

63″

2

4″

5″

2

3″

5″

97³⁄₄″

41¹⁄₄″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-21

37″

112¹⁄₂″

63″

2

4″

5″

3

3″

5″

102¹³⁄₁₆″

41¹⁄₄″

35⁹⁄₁₆″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-22

37″

117⁹⁄₁₆″

63″

2

4″

5″

3

3″

5″

107⁷⁄₈″

41¹⁄₄″

40⁵⁄₈″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-23

37″

122⁵⁄₈″

63″

2

4″

5″

3

3″

5″

112¹⁵⁄₁₆″

46³⁄₈″

40⁵⁄₈″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

LCE-24

37″

127¹¹⁄₁₆″

63″

2

4″

5″

3

3″

5″

118¹⁄₁₆″

46³⁄₈″

45¹¹⁄₁₆″

18¹⁄₂″

16″

20¹⁄₂″

16″

3′

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*These dimensions are approximate.

BOILER RATINGS & DIMENSIONS

Image 46
Contents Series LC/LCE Table of Contents Using this Manual Special Attention BoxesPreinstallation Accessibility ClearancesCombustion and Ventilation AIR Clearance from Combustible ConstructionChimney or Vent Boiler Setting Foundation LayoutVerify Components Installation SurveyPlanning the Layout Foundation Lengths2A Series LC Shipping List Lwco2B Series LCE Shipping List Interm BackStandard and Optional Jacket Cartons, Top/Side Panels Standard and Optional Sections for Knockdown BoilersStandard and Optional Jacket Cartons, Front/Back Panels 6A Burner Mounting PlatesTrim Cartons 6B Burner Mounting PlatesControl Cartons Assembled Block Boiler Place the BoilerPackaged Boiler Knockdown BoilerApply Silcone Sealant Place the Boiler Series LC Boiler Assembly Right Side View Series LCE Boiler Assembly Right Side View Torque Specification/Procedure ModelLC/LCE Boiler Section Assembly Sequence Hydrostatic Test the Boiler Install Coils or PlatesTankless Coil Ratings Apply Cleanout Cover Plates Install Flue CollarInstall Flue Baffles Install Chamber LinerPipe the Boiler LOW System TemperatureLow Return Temperature Piping, General Preparation@ 20F Output Rise Return ConnectionsSize Header Constant Low Temperature Variable Low TemperatureChilled Water Systems Multiple Boiler InstallationsHigh Flow Rate Piping Piping for Variable Low Temperature Systems, Single Boiler Pipe the Boiler Pipe the Boiler Assemble the Jacket Jacket Assembly Venting Install the BurnerInstall Burner Mounting Plate Burner ApplicationBeckett Carlin Gordon Power Webster Inches Piatt Chamber Burner Front Plate Extension Past Jacket InchesConnect Fuel Piping Install Fuel OIL PipingInstall GAS Supply Piping GeneralPipe Pipe LengthSpecific Gravity Multiply Capacity by Install Drain Valve Install Controls and TrimInstall Safety Relief Valve Install LOW Water CutoffsInstall Control Wiring Connect Supply WiringPipe Tankless Heaters if Used Control and Pipe Tapping Locations Suggested Piping Single Tankless Coil Installation Fill the Boiler Starting the BoilerCheck the Piping RUN Burner CHECK-OUTTypical Combustion Chamber Pressure and Boiler Draft Loss Check Boiler ControlsModel Combustion Chamber Pressure Boiler Draft Loss Maintenance Placing Boiler in Operation Maintenance AnnualTo Shut Down the Boiler Monthly Maintenance Daily MaintenanceBoiler Ratings & Dimensions Series LC/LCE Boiler RatingsSeries LC Dimensional Diagram Series LC/LCE Boiler Dimensions Series LC/LCE Boiler DimensionsRepair Parts Series LC Boiler Assembly1A Series LC Repair Parts Description Part Selection Information Stock Code1B Series LC Repair Parts Series LCE Boiler Assembly 2A Series LCE Repair Parts 2B Series LCE Repair Parts Page Page Series LC/LCE