Cable length | Cross section | |
| < 16 A | < 25 A |
up to 20 m | 1.5 mm2 | 2.5 mm2 |
20 to 50 m | 2.5 mm2 | 4.0 mm2 |
Guarantee
Our general conditions of business are applica- ble with regard to the guarantee.
Unauthorised modifications to the appliance, the use of incorrect brushes in addition to using the appliance in a way other than for the intended purpose exempt the manufacturer from any liability for the resulting damage.
Tests and approvals
Electrical tests must be performed in accord- ance with the provisions of safety regulations (BGV A3) and to DIN VDE 0701 Part 1 and Part
3.In accordance with DIN VDE 0702 these tests must be performed at regular intervals and after repairs or modifications.
Risks
Electrical components
DANGER
Electric shock due to faulty mains connecting lead.
Touching a faulty mains connecting lead can result in serious or even fatal injuries.
1.Do not damage the mains power lead (e.g. by driving over it, pull- ing or crushing it).
2.Regularly check whether the power cord is damaged or shows signs of ageing.
3.Have the faulty mains connecting lead replaced by your
DANGER
The upper section of the vacuum cleaner contains live components.
Contact with live components leads to serious or even fatal injuries.
1.Never spray water on to the upper section of the vacuum cleaner.
ATTIX 9 STD
CAUTION
Appliance socket *)
The appliance socket is only de- signed for the purposes defined in the operating instructions.
1.The connection of different appli- ances can result in damage.
2.Prior to plugging in an appliance, always switch off the vacuum cleaner and the appliance that is to be connected.
3.Read the operating instructions to the appliance to be connected and observe the safety notes contained in these.
CAUTION
Damage due to unsuitable mains voltage.
The appliance can be damaged as a result of being connected to an unsuitable mains voltage.
1.Ensure that the voltage shown on the rating plate corresponds to the voltage of the local mains power supply.
Picking up liquids
CAUTION
Picking up liquids.
Due to their construction vacuum cleaners with a removable tank (SD) do not have an automatic level indi- cator. There is a risk of damage to the vacuum cleaner due to overfilling or of damage due to leakage of the picked up liquid.
1.Never pick up more than 40 litres at once.
2.Switch off the vacuum cleaner and empty the dirt tank.