Wayne-Dalton 5140 Parallel with door, Or door stop too tightly against face, Door, Sides equally

Page 30

 

 

 

Angle bolted to ceiling

 

 

Rear Support Continued...

PERFORATED

member and parallel to

 

 

 

ANGLE

door

 

 

 

 

 

Tools Needed:

supplied). Horizontal tracks must be level

(3) 5/16”

 

 

and parallel with door.

NUTS

Horizontal

 

 

 

 

NOTE: If perforated angle is installed

 

track

 

 

over drywall, use 5/16” x 2” hex head lag

 

 

 

 

screws.

(3) 5/16”

 

 

 

Adjust weather seal (if necessary) and

 

 

 

now permanently attach the weather

BOLTS

 

Angle

 

seal or door stop to both door jambs and

 

 

 

header. (They were temporarily attached

 

Vertical

 

to the jambs in PREPARING The OPENING

 

 

 

 

Angle

 

on page 10.) Avoid pushing weather seal

 

Bolt must extend into

 

 

 

 

or door stop too tightly against face of

 

the track to serve as

 

 

door.

 

a roller stop

 

 

NOTE: If an idrive® opener will be

Sound Framing Members

 

 

 

installed, position horizontal tracks one

 

 

 

hole above level when securing it to rear

 

 

 

 

supports.

 

 

 

 

Now, lift door and check it’s balance.

 

Perforated

 

WARNING

 

ANGLE

 

 

 

 

 

Prior to winding or making

 

Perforated ANGLE - BOLTED

adjustments to the springs,

 

USING (2) 5/16” X 1-5/8” HEX HEAD

ensure you’re winding in the

 

LAG SCREWS TO CEILING MEMBER

proper direction as stated in

 

AND PARALLEL TO WIDTH OF DOOR.

the Installation Instructions.

 

Space lag screws no further

Otherwise, the spring fittings may

 

 

than 24” apart.

release from spring if not wound

 

 

 

in the proper direction and could

 

 

result in severe or fatal injury.

HORIZONTAL

BOLT MUST EXTEND INTO THE TRACK

Adjust, if door lifts by itself (hard to pull

TO SERVE AS A ROLLER STOP

down) or if door is difficult to lift (easy to

TRACK

 

pull down). Anytime spring adjustments

 

Sound Framing Members

are made you must loosen the lock nuts

 

 

 

and retighten both lock nuts afterwards.

 

PERFORATED ANGLE

To adjust spring(s), only add or remove 1/4

 

 

 

turn on the counter at a time. Adjust both

 

 

sides equally.

 

Perforated ANGLE -BOLTED USING

IMPORTANT: Do not add or remove

 

 

(2) 5/16” X 1-5/8” HEX HEAD LAG

more than 1 spring turn from

 

 

SCREWS TO CEILING Members

specified amount. If the door still

 

 

AND PARALLEL TO WIDTH OF DOOR.

does not operate easily, lower

 

the door into the closed position,

 

Attach vertical perforated angle

UNWIND SPRING(S) TO ZERO, and

 

between the (2) 5/16” X 1-5/8”

recheck the following items:

 

HEX HEAD LAG SCREWS, securing

1.) Check the door for level.

 

perforated angle to ceiling

2.) Check the TorqueMaster® spring tube

 

members.

and flagangles for level and plumb.

HORIZONTAL

BOLT MUST EXTEND INTO THE TRACK

3.) Check the distance between the

TRACK

flagangles - must be door width

TO SERVE AS A ROLLER STOP

 

plus 3-3/8” to 3-1/2”.

 

PERFORATED ANGLE

4.) Check the counterbalance cables

 

 

for equal tension - adjust if

 

 

necessary.

 

 

5.) Rewind the spring(s).

 

Weather

6.) Make sure door isn’t rubbing on

 

jambs.

 

seal

NOTE: As a safety feature, the right hand

 

 

end bracket cannot be disassembled

 

 

for service until the spring is completely

 

 

unwound and the counter cover reads

 

Jamb

zero.

 

 

 

After door installation is completed, refer

 

 

to the idrive® owner’s manual.

(3) 5/16” BOLTS

Permanently attached

 

& NUTS

 

Weather seal

 

 

30Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer.

To find your Wayne-Dalton dealer; refer to your local yellow pages / business listings or go to Find a dealer area online at www.wayne-dalton.com

Image 30
Contents 5120 Table of Contents Package Contents Door Section Identification Tools Required Failure to use approved Torsion Spring RemovalFor Standard Lift Winding bars can cause Spring energy to be releasedBracket will always have a drive gear Using an electric drill HighCounter cover when counting Head will be pluggedTorqueMaster Spring RemovalExtension Spring Removal Removing the Old DoorPreparing the Opening Installation Attaching Quick Install FlagAngle to Vertical Track Installing Q.I. Jamb Brackets Horizontal AngleDrums Bottom SectionVertical Track Stacking SectionsTop Brackets BarBar Asymmetrical Operator BracketTop Section Portion of horizontal track down to Tools Needed To install horizontal track, placeTo the slot in the flagangle using Remove the nail that was temporarilyTorqueMaster Spring Tube Center Bracket BushingGarage looking out Idrive InstallationPlug the motor power cord into Opener Right hand end of the TorqueMasterCable Drum Installation Drive Gear Installation End BracketsCounter Installation Securing Center Bracket AssemblyPositioning Support Bracket Attaching Disconnect Cables Mounting DisconnectHandle Bracket Attaching Disconnect Handle Failure to place vice clamps Cable AdjustmentsSecuring Door Onto vertical Track canSetting Spring Tension Winding Bolt RotationDrum Wrap Installation Rear SupportParallel with door Adjustments to the springsInstallation Instructions Or door stop too tightly against faceSide Lock Sold Separately Step Plate Sold Seperately Pull RopeAppropriate 1/2 1 room permitting above of the high Determine the Wayne-DaltonTrack radius being used Trolley to operator bracketTrolley Installation for Low Headroom Operator Rail Trolley OperatorOpens if Photoelectric EYE System Suitable mountingCleaning Cleaning Your Garage DoorPainting Maintenance PaintingLimited Warranty Models 5120