Burnham K50 manual Series 5B Jackets

Page 91

TABLE 4A

SERIES 5B JACKETS

 

 

 

Number in ( ) in Table Relates to Corresponding Number in

in Figure 71

 

 

 

 

PART NUM-

 

ITEM

PART SIZE

 

 

 

 

BOILER SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BER

 

5006B

5007B

5008B

5009B

5010B

5011B

5012B

5013B

5014B

5015B

 

 

 

 

60413059

*5005B Front Top Panel

17-1/2 x

28-5/8

 

 

 

 

 

(1) & (2)

(1)

 

 

 

60413069

5006B

Front Top Panel

17-1/2 x 34-1/16

(1)

 

 

 

 

 

(2)

(1) & (2)

(1)

 

60413079

5007B

Front Top Panel

17-1/2 x

39-1/2

 

(1)

 

 

 

 

 

 

 

 

60413089

5008B

Front Top Panel

17-1/2 x 44-15/16

 

 

(1)

 

 

 

 

 

 

 

60413099

5009B

Front Top Panel

17-1/2 x

50-3/8

 

 

 

(1)

 

 

 

 

 

 

60413109

5010B

Front Top Panel

17-1/2 x 55-13/16

 

 

 

 

(1)

 

 

 

 

 

7041316

Front Top Int. Panel

6-1/16 x 12

 

 

 

 

 

(9)

(9)

(9)

(9)

(9)

6041327

Center Top Int. Panel

6-1/16 x 6-7/8

 

 

 

 

 

(47)

(47)

(47)

(27)

(47)

6041328

Rear Top Int. Panel

3-25/32 x 6-1/16

 

 

 

 

 

(10)

(10)

(10)

(10)

(10)

60413052

*5005B Upper Rear Panel

24-1/2 x 26-5/16

 

 

 

 

 

(23) & (24)

(24)

 

 

 

60413062

5006B

Upper Rear Panel

24-1/2 x

31-3/4

(23)

 

 

 

 

 

(23)

(23) & (24)

(23)

(23) &

60413072

5007B

Upper Rear Panel

24-1/2 x 37-3/16

 

(23)

 

 

 

 

 

 

(24)

 

 

 

 

 

 

 

(24)

60413082

5008B

Upper Rear Panel

24-1/2 x

42-5/8

 

 

(23)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60413092

5009B

Upper Rear Panel

24-1/2 x 48-1/16

 

 

 

(23)

 

 

 

 

 

 

60413102

5010B

Upper Rear Panel

24-1/2 x

53-1/2

 

 

 

 

(23)

 

 

 

 

 

60413053

*5005B Lower Rear Panel

9-1/2 x 26-5/16

 

 

 

 

 

(27) & (28)

(27)

 

 

 

60413063

5006B

Lower Rear Panel

9-1/2 x 31-3/4

(27)

 

 

 

 

 

(28)

(27) & (28)

(27)

 

60413073

5007B

Lower Rear Panel

9-1/2 x 37-3/16

 

(27)

 

 

 

 

 

 

 

 

60413083

5008B

Lower Rear Panel

9-1/2 x 42-5/8

 

 

(27)

 

 

 

 

 

 

 

60413093

5009B

Lower Rear Panel

9-1/2 x 48-1/6

 

 

 

(27)

 

 

 

 

 

 

60413103

5010B

Lower Rear Panel

9-1/2 x 53-1/2

 

 

 

 

(27)

 

 

 

 

 

60413021

Upper Rear Int. Panel

7-5/16 x

25-1/2

 

 

 

 

 

(31)

(31)

(31)

(31)

(31)

60413031

Lower Rear Int. Panel

7-5/16 x

10-1/2

 

 

 

 

 

(32)

(32)

(32)

(32)

(32)

6041329

Upper Left End Panel

36 x

26

(13)

(13)

(13)

(13)

(13)

(13)

(13)

(13)

(13)

(13)

60413071

Lower Left End Panel

36 x 10-1/2

(14)

(14)

(14)

(14)

(14)

(14)

(14)

(14)

(14)

(14)

70413054

*5005B Upper Front Panel

24-1/2 x 26-5/16

 

 

 

 

 

(33) & (34)

(33)

 

 

 

70413064

5006B

Upper Front Panel

24-1/2 x

31-3/4

(33)

 

 

 

 

 

(34)

(33) & (34)

(33)

(33) &

70413074

5007B

Upper Front Panel

24-1/2 x 37-6/16

 

(33)

 

 

 

 

 

 

(34)

 

 

 

 

 

 

 

(34)

70413084

5008B

Upper Front Panel

24-1/2 x

42-5/8

 

 

(33)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70413094

5009B

Upper Front Panel

24-1/2 x 48-1/16

 

 

 

(33)

 

 

 

 

 

 

70413104

5010B

Upper Front Panel

24-1/2 x

53-1/2

 

 

 

 

(33)

 

 

 

 

 

* For Multiple Usage Only

91

Image 91
Contents Series 5B Section I Equipment Check List Important Information Canadian Equipment Check List Canadian Equipment Check List Natural GAS Maximum 14 W.C. Minimum 5.5 W.C Dimensional DataProvide Combustion and Ventilation AIR Do not Install this Boiler on CarpetingSingle Manifold Base 5006B Thru 5014B Section Boilers BASE-BURNER-MANIFOLD AssemblysDual Manifold Bases 5015B Thru 5026B Section Boilers LEH Section on Base Assembly of Center SectionsArrangement of Sections and Canopys Purpose of Tappings and Their Locations Open Steam or Water Trim CartonTesting Boiler Assembly for Leaks Installation of BUILT-IN HeaterConnect Supply and Return Piping to Heating System Attachment of Flue Covers Sealing of BASE, Installation Flue Covers and CanopiesOxygen Corrosion Page Page Page Page Sizes 5006B Thru 5019B Recommended Water Boiler PipingSupply Connection & I Return Connection Supply Connections & 2 Return ConnectionsInstallation of Jacket Support Brackets to Base END Panels Installation of Jacket Parts Common to ALL Boiler SizesPage Exploded View of Jacket 6 Thru 10 Section Boilers Securing of CANOPY/DRAFTHOOD CANOPY/DRAFTHOOD Mounting Diagram Exploded View of Jacket 11 Thru 19 SECT. Boilers Completion of Jacket Installation 11 Thru 26 Section Boilers Exploded View of Jacket 20 Thru 22 SECT. Boilers Exploded View of Jacket 26 SECT. Boilers Steam Trim and Controls Shutoff Valve Between Safety ValveMounting Elevations of M&M 150 and a 67M Float Lwco Water Trim and Controls Open GAS Train Cartons Recommended Piping to BUILT-IN Tankless HeatersOpen Gas Controls Cartons Pilot Piping EI Control System Robertshaw7000 A B Thru 5009B Installation of S8610M ModuleA B Thru 5026B NAT. GAS Canada 5006B Thru 5026B NAT. GAS Pilot Piping EI Control System V88AInstallation of Pilot Safety Switch EO Control System Installation of Pilot Safety SwitchPilot Piping EO Control System EE Control System Installation of EO and EE Mounting Bracket and ControlsPilot Piping EE Control System Sect. and larger boilersPilot Piping EOP Control System Installation of Pilot Safety Switch EOP Control SystemPilot Piping EEP Control System EEP Control SystemPage Single Vent System Manifold Vent System VentingPage General Section IV OperationTable IV Water Content Control Variations CondensationBe sure power is off when checking high voltage connections A B Thru 5009B Canada 5006B Thru 5014B Schematic Wiring Diagram EI Control System V88 GAS TrainSequence of Operation A B Thru 5014BEI Control System Schematic wiring diagram 15 Thru 26 SECT. BoilersSequence of Operation Page Pilot Failure Safety Switch CircuitWiring diagram 6 Thru 14 SECT. Boilers Proceed to Paragraph 15- Minimum Input Wiring diagram 15 Thru 26 SECT. Boilers Operating and safety controls. Should any EE Control System Wiring diagram 15 Thru 26 SECT. Boilers Proceed to Paragraph 15- Minimum Input Wiring Diagram 6 Thru 14 SECT. Boilers EOP Control System Turn on Main Power Switch. Main Power Light will light Wiring Diagram 15 Thru 26 SECT. Boilers EOP Control System Safety Switch Circuit Wiring Diagram 6 Thru 14 SECT. Boilers EEP Control System Pilot Failure Safety Switch Circuit Wiring Diagram 15 Thru 26 SECT. Boilers EEP Control System Make sure all manual resets are activated where applicable Normal Operation Sequence Page Check GAS Input Rate to Boiler Screw Minimum Input AdjustmentsV8944B Combination Valve Motorized Modulating ActuatorTest Ignition System Safety SHUT-OFF Device AS Follows Combustion Chamber BURN-OFF Thermocouple Pilot SystemRemoval of Jacket Front Panel Section V ServiceAvoid Breathing Fiber Particulates and Dust Lubrication Cleaning of FluewaysPilot Locations Honeywell Q179D Pilot w/THERMOCOUPLE Main Burner Flame AdjustmentPilot Flame Honeywell Q3481B Pilot FlameHoneywell Q327A Pilot w/THERMOCOUPLE Pilot Flame Honeywell Q179C PilotDo not drain water below gauge glass Jackets Base PartsNumber in in Table Relates to Corresponding Number Series 5B Base Parts 5006B thru 5014BBase Parts 5015B 5016B 5017B 5018B 5019B 5020B 5021B 5022B 5024B 5026B Series 5B Base Parts 5015B thru 5026BBase Parts Boiler Size Quantity Part Size CanopyIntegral Canopy Drafthoods & Sections Series 5B Section Replacement Chart Series 5B Base / Pilot Assemblies Series 5B Jackets 60413075 5007B Lower Top Panel 2 x 37-3/16 60413085 5008B 2 x 20-7/8 Complete Jackets Jackets Boiler Size 5006B 5008B 5009B 5014B 5015B 5016B 5017B 5026B Boiler SizeV88A GAS Trains Canada Natural GAS only Fluid Power GAS Trains USA 5006B 5009B 5015B 5016B 5017B 100Diaphragm Valve LO-HI-LO GAS Train Canada Natural GAS only 101102 Fluid Power GAS Trains CanadaIgnition Module & Support Bracket EI Control System 103104 Pilot Safety SwitchDescription Manifold Module Support L62GB-3C A. 5010B-5026B NAT. GAS Canada 5006B-5026B NAT. GAS 105Transformer & Pilot Line Regulator EO Control System 106107 108 109 110 EOP & EEP Control Panel 111112 EI Control System Pilot Assembly6236007 NAT. GAS 113EI GAS 6236003 NAT. GAS 114Not Available for LP 115 Date Service Performed116 Limited Warranty