PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction | U.S. EPA | Average | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
Chlorine Taste/Odor | N/A | 2.0 mg/L | N/A | 0.04 mg/L | N/A | 98% | 994707 |
Particulate | N/A | 610,000/mL* | N/A | 154/mL | N/A | 99% | 994711 |
|
|
|
|
|
|
|
|
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
Cyst | 99.95%** | 89,250/mL* | 6/mL | 2.3/mL | 99.993% | 99.997% | 994710 |
Turbidity | 0.5 NTU | 29 NTU | 0.12 NTU | 0.09 NTU | 99.59% | 99.69% | 994710 |
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.015 mg/L | 0.16 mg/L*** | 0.001mg/L | 0.001 mg/L | 99.4% | 99.4% | 994708 |
Lead: @ pH 8.5 | 0.015 mg/L | 0.16 mg/L*** | 0.002 mg/L | 0.001 mg/L | 98.8% | 99.4% | 994709 |
|
|
|
|
|
|
|
|
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
part# 4396164. 2002 suggested retail price of $39.95 U.S.A./ $49.95 Canada. Prices are subject to change without notice.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the front cover or “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
|
|
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International.
20