Installation | TANDBERG Director Videoconferencing System |
|
|
Touchscreen Calibration
Once the system is installed and functioning, it is recommended that the SMART BoardTM 3000i touch screen be calibrated.
First touch and hold the top left corner of the screen for 5 seconds. This will give you a hidden ‘Tools’ setup screen. Then touch and hold the bottom right corner of the ‘Tools’ screen for another 5 seconds.
Press and hold for 5 seconds
Press and hold for 5 seconds
You will get the following
Selecting ‘Calibrate System’ will display a series of
In rare cases, it may not be possible to reach this page because the calibration is too far off the screen. You can connect direct to the Director Application Module and enter a simple command:
•Connect your PC with a “straight through” RS232 cable to PROGRAM on the rear interface panel of the Director Applications Module.
•Open a terminal program such as ’HyperTerminal’ or ’PROCOMM Plus’.
•Set the baud rate settings to 115200,N, 8,1.
•Type the command CALTOUCH and <enter>.
•Touch the crosshairs on the screen to calibrate the system.
22