Southbend STRG-5D, STRG-3D manual Location of Connections and Vents, Drain Connection

Page 16

INSTALLATION

STRATOSTEAM COUNTERTOP STEAMER

Figure 6

Location of Connections and Vents

STEP 3: DRAIN CONNECTION

The drain outlet is located on the back of the steamer, as shown in Figure 6. The drain connector on the steamer is 1" NPT female.

Position the steamer near, but not on top of, an open floor drain. DO NOT directly plumb the steamer unless you also install an “open funnel” downstream of this connection in the drain system. Make the drain line from the steamer to the air gap above the “open funnel” as short as possible. There should be no horizontal piping between the steamer and the air gap above the open funnel. The open funnel is intended to eliminate any water from entering the steamer because of a blocked drain, and it also prevents any back pressure within the steamer cavity. Any connection that allows the build-up of back pressure in the steamer (such as a reduction in pipe size to a line smaller than 1", or more than one 90-degree angle in the line prior to the open funnel drain discharge point) may cause personal or property damage and will therefore void the warranty. The steamer is a pressureless, free-venting steam cooker and will not operate properly unless the drain line is short, at a steep angle, and open! See Figure 7 on the next page.

PAGE 16 OF 50

OWNERS MANUAL 1185290

Image 16
Contents StratoSteam Countertop Steamer Safety Precautions Introduction Location of Serial PlatesDimensions ClearancesDimensions Electrical Requirements GAS Pressure RequirementsWater Requirements Drain RequirementsTroubleshooting by Operator StartupOperation ShutdownTimer ControlsCooking Tips Suggested Cooking Times Cleaning & Maintenance Daily Cleaning and MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesInstallation Unpacking Attach LegsAttach Legs Installation on Countertop Attach to CountertopMounting on Cabinet Base Stacking TWO SteamersLocation of Connections and Vents Drain ConnectionWater Connection Water DrainWater Connection Testing the GAS Supply Piping GAS ConnectionElectrical Connection SHUT-DOWN and WIPE-CLEAN Steamer Check the InstallationCheck Steamer Operation Service Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams HOW the Steamer OperatesHow the Steamer Operates Steamer Not Heating Up, Power Light Is Not Lit Disconnect Power AT Circuit BreakerCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Hot Surface Ignitor Glows Red, But Burners Not On Hot Surface Ignitor Does Not Glow Red Not All Burners Ignite Burner Lights But Goes Out Within a Few Seconds Symptom Possible Cause Cure Power Switch Check Disconnect Power AT Circuit BreakerTimer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt and 115 Volt Models Parts Diagram PartsStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Burner Assemblies, Thermocouple, and Ignition Module Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRG-3D STRG-5D