STEP 4: WATER CONNECTION

 

WARNING

Do not connect steamer to a hot water line. A hot water connection will damage the steamer.

NOTICE

To meet warranty requirements, the supply water must meet the following specifications:

Pressure

30 to 60 PSI (205 to 410 kPa)

Total Dissolved Solids (TDS)

60 PPM or less

Hardness

2 grains (35 PPM) or less

pH

7.0 to 7.5

Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 6. The connector on the steamer is a 1/4" compression fitting.

NOTE: To facilitate cleaning, and allow access to rear of the steamer, flexible connections are recommended. A shut off valve at (or near) the rear of the steamer is highly recommended. Also, an accessible water filter is recommended to help keep water quality within the requirements described above. See Figure 8 below.

Figure 8

 

Water Connection

 

Cold

 

Water

Steamer

Supply

 

Shut Off

Filter

Valve

 

OWNERS MANUAL 1185290

PAGE 17 OF 50

Image 17
Contents StratoSteam Countertop Steamer Safety Precautions Location of Serial Plates IntroductionClearances DimensionsDimensions GAS Pressure Requirements Electrical RequirementsWater Requirements Drain RequirementsStartup Troubleshooting by OperatorOperation ShutdownControls TimerCooking Tips Suggested Cooking Times Daily Cleaning and Maintenance Cleaning & MaintenanceSTAINLESS-STEEL Surfaces Periodic DE-LIMING AS NeededInstallation Attach Legs Attach LegsUnpacking Attach to Countertop Installation on CountertopMounting on Cabinet Base Stacking TWO SteamersDrain Connection Location of Connections and VentsWater Connection Water DrainWater Connection GAS Connection Testing the GAS Supply PipingElectrical Connection Check Steamer Operation Check the InstallationSHUT-DOWN and WIPE-CLEAN Steamer Service HOW the Steamer Operates Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring DiagramsHow the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Hot Surface Ignitor Glows Red, But Burners Not On Hot Surface Ignitor Does Not Glow Red Not All Burners Ignite Burner Lights But Goes Out Within a Few Seconds Symptom Possible Cause Cure Disconnect Power AT Circuit Breaker Power Switch CheckTimer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt and 115 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Burner Assemblies, Thermocouple, and Ignition Module Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRG-3D STRG-5D