Southbend STRG-5D, STRG-3D manual Power Switch Check, Disconnect Power AT Circuit Breaker

Page 32

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 18

Power Switch Check

1.DISCONNECT POWER AT CIRCUIT BREAKER.

5.Remove right side panel.

6.Turn control lever from OFF to ON and then from ON to OFF while looking to see that the power switch is properly actuating when the lever moves.

7.Disconnect the connector (PL1) that connects the control-panel component wires to the wiring harness.

8.As shown above, place one test lead on terminal TB6 of the terminal board and the other test lead on Pin 3 of connector PL1 (the socket half, which is wired to the control panel).

9.Check for continuity with control lever in OFF position (there should not be continuity).

10.Check for continuity with control lever in ON position (there should be continuity).

11.Repeat steps 5 through 7 with one test lead on terminal TB5 of the terminal board and the other test lead on Pin 6 of connector PL1 (as shown above).

12.Place one test lead on PL1 Pin 3 and the other test lead on PL1 Pin 6 (as shown above). Check for continuity with control lever in the ON position (there should not be continuity).

13.If continuity checks are incorrect, replace power switch.

14.Reconnect lead wires.

PAGE 32 OF 50

OWNERS MANUAL 1185290

Image 32
Contents StratoSteam Countertop Steamer Safety Precautions Introduction Location of Serial PlatesDimensions ClearancesDimensions Electrical Requirements GAS Pressure RequirementsWater Requirements Drain RequirementsTroubleshooting by Operator StartupOperation ShutdownTimer ControlsCooking Tips Suggested Cooking Times Cleaning & Maintenance Daily Cleaning and MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesInstallation Attach Legs Attach LegsUnpacking Installation on Countertop Attach to CountertopMounting on Cabinet Base Stacking TWO SteamersLocation of Connections and Vents Drain ConnectionWater Connection Water DrainWater Connection Testing the GAS Supply Piping GAS ConnectionElectrical Connection Check Steamer Operation Check the InstallationSHUT-DOWN and WIPE-CLEAN Steamer Service Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams HOW the Steamer OperatesHow the Steamer Operates Steamer Not Heating Up, Power Light Is Not Lit Disconnect Power AT Circuit BreakerCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Hot Surface Ignitor Glows Red, But Burners Not On Hot Surface Ignitor Does Not Glow Red Not All Burners Ignite Burner Lights But Goes Out Within a Few Seconds Symptom Possible Cause Cure Power Switch Check Disconnect Power AT Circuit BreakerTimer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt and 115 Volt Models Parts Diagram PartsStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Burner Assemblies, Thermocouple, and Ignition Module Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRG-3D STRG-5D