Southbend STRG-5D, STRG-3D manual Water Solenoid Check

Page 36

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 22

 

Water Solenoid Check

 

 

Ohms

 

Volts

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove right side panel.

3.Disconnect wires B6 and B7 from water solenoid lead wires.

4.Place test probes into water solenoid lead wires as shown above.

5.Resistance should be approximately 800 ohms. Replace if necessary.

6.Apply waterline pressure to water inlet. Water should not leak out of the compression fittings. If necessary, replace water solenoid. Check to see that water is slowly running into the cooking cavity.

7.Reconnect solenoid lead wires and reconnect power to steamer. When power is turned on with the steamer cool, the solenoid should “click.” If no click is heard, test for 200 to 240 volts on wires B6 and B7. If 200 to 240 volts is present and the water solenoid does not click, replace water solenoid.

PAGE 36 OF 50

OWNERS MANUAL 1185290

Image 36
Contents StratoSteam Countertop Steamer Safety Precautions Introduction Location of Serial PlatesDimensions ClearancesDimensions Electrical Requirements GAS Pressure RequirementsWater Requirements Drain RequirementsTroubleshooting by Operator StartupOperation ShutdownTimer ControlsCooking Tips Suggested Cooking Times Cleaning & Maintenance Daily Cleaning and MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesInstallation Attach Legs UnpackingAttach Legs Installation on Countertop Attach to CountertopMounting on Cabinet Base Stacking TWO SteamersLocation of Connections and Vents Drain ConnectionWater Drain Water ConnectionWater Connection Testing the GAS Supply Piping GAS ConnectionElectrical Connection Check the Installation SHUT-DOWN and WIPE-CLEAN SteamerCheck Steamer Operation Service Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams HOW the Steamer OperatesHow the Steamer Operates Steamer Not Heating Up, Power Light Is Not Lit Disconnect Power AT Circuit BreakerCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Hot Surface Ignitor Glows Red, But Burners Not On Hot Surface Ignitor Does Not Glow Red Not All Burners Ignite Burner Lights But Goes Out Within a Few Seconds Symptom Possible Cause Cure Power Switch Check Disconnect Power AT Circuit BreakerTimer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt and 115 Volt Models Parts Diagram PartsStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Burner Assemblies, Thermocouple, and Ignition Module Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRG-3D STRG-5D