Southbend STRG-3D, STRG-5D manual Water Train Parts

Page 45

STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Water Train Parts

See drawing on following page.

Key

Part Number

Qty

Description

1

1166800

2

UNION, STRAIGHT

2

1173218

1

FITTING, 3/8 NPT X 3/8 CC ELBOW

3

1174620

1

SPRAY NOZZLE

4

1174933

1

SOLENOID WATER VALVE (240 VAC)

4

1185285

1

SOLENOID WATER VALVE (115 VAC)

5

1176384

1

NIPPLE, CLOSE 1/8 NPT X 3/4 LONG

6

1184260

1

STRAINER, Y IN-LINE 1/8 NPT FEM.

7

1184261

1

TEE, 1/8 STREET

8

1184262

1

REDUCER, 3/8 TO 1/8 MPT

9

1185149

1

TUBE 1/4 WATER INLET

10

1185150

1

UNION, BULKHEAD COMP 1/4 X 1/4

11

1185275

1

HEAT EXCHANGE, W/A

12

P4119

1

ELBOW, BRASS

13

P5552

2

FITTING, 1/8 NPT X 1/4 CC STRAIGHT 1/4 M X 3/8 CC

14

1176385

1

FITTING, 1/8 NPT X 3/8 CC STRAIGHT

15

PP-636

1

REGULATOR, FLOW

16

1185292

1

TUBE FLEX, 3/8 X 18

17

1187478

1

TUBE FLEX, 3/8 X 12

18

1183264

1

TUBE FLEX, 1/4 X 9

OWNERS MANUAL 1185290

PAGE 45 OF 50

Image 45
Contents StratoSteam Countertop Steamer Safety Precautions Location of Serial Plates IntroductionClearances DimensionsDimensions GAS Pressure Requirements Electrical RequirementsWater Requirements Drain RequirementsStartup Troubleshooting by OperatorOperation ShutdownControls TimerCooking Tips Suggested Cooking Times Daily Cleaning and Maintenance Cleaning & MaintenanceSTAINLESS-STEEL Surfaces Periodic DE-LIMING AS NeededInstallation Attach Legs UnpackingAttach Legs Attach to Countertop Installation on CountertopMounting on Cabinet Base Stacking TWO SteamersDrain Connection Location of Connections and VentsWater Drain Water ConnectionWater Connection GAS Connection Testing the GAS Supply PipingElectrical Connection Check the Installation SHUT-DOWN and WIPE-CLEAN SteamerCheck Steamer Operation Service HOW the Steamer Operates Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring DiagramsHow the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Hot Surface Ignitor Glows Red, But Burners Not On Hot Surface Ignitor Does Not Glow Red Not All Burners Ignite Burner Lights But Goes Out Within a Few Seconds Symptom Possible Cause Cure Disconnect Power AT Circuit Breaker Power Switch CheckTimer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt and 115 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Burner Assemblies, Thermocouple, and Ignition Module Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRG-3D STRG-5D