Setting Terminal Parameters

21

To number the user interface by relative number, represented by interface + number assigned to each type of user interface:

AUX user interface = AUX 0.

The first VTY interface = VTY 0, the second one = VTY 1, and so on.

Tasks for configuring the user interface are described in the following sections:

Entering the User Interface View

Configuring the Attributes of the AUX (Console) Port

Configuring the Terminal Attributes

Managing Users

Configuring the Attributes of a Modem

Configuring Redirection

Displaying and Debugging User Interface

Entering the User Interface View

Use the user-interfacecommand (see Table 4) to enter a user interface view. You can enter a single user interface view or multi-user interface view to configure one or more user interfaces.

Perform the following configuration in system view.

Table 4 Enter User Interface View

Operation

Command

 

 

Enter a single user interface view or multi user

user-interface[ type ] first-number [

interface views

last-number ]

 

 

Configuring the Attributes of the AUX (Console) Port

Use the speed, flow control, parity, stop bit, and data bit commands (see Table 5) to configure these attributes of the AUX (Console) port.

Perform the following configurations in user interface (AUX user interface only) view.

Table 5 Configure the Attributes of the AUX (Console) Port

Operation

Command

 

 

Configure the transmission speed on AUX

speed speed-value

(Console) port. By default, the transmission

 

speed is 9600bps

 

Restore the default transmission speed on

undo speed

AUX (Console) port

 

Configure the flow control on AUX (Console) port. By default, no flow control is performed on the AUX (Console) port

flow-control { hardware none software }

Restore the default flow control mode on AUX

undo flow-control

(Console) port

 

Configure parity mode on the AUX (Console)

parity { even mark none odd space }

port. By default, there is no parity bit on the

 

AUX (Console) port

 

Restore the default parity mode

undo parity

Page 21
Image 21
3Com 10014298 manual Entering the User Interface View, Configuring the Attributes of the AUX Console Port