256CHAPTER 11: SYSTEM MANAGEMENT

Configuring System Basics

Debugging the System

Testing Tools for Network Connection

Logging Function

This section describes the following basic system configuration tasks:

Setting the System Name

Setting the System Clock

Setting the Time Zone

Setting Daylight Saving Time

Setting the System Name

Perform the following commands in system view.

Table 282 Setting the System Name

Operation

Command

 

 

Set the switch name

sysname sysname

Restore the switch name to the default name

undo sysname

 

 

Setting the System Clock

Perform the following command in user view.

Table 283 Setting the System Clock

Operation

Command

 

 

Set the system clock

clock datetime HH:MM:SS

 

YYYY/MM/DD

 

 

Setting the Time Zone

You can configure the name of the local time zone, and the time difference between the local time and the standard Universal Time Coordinated (UTC).

Perform the following commands in user view.

Table 284 Setting the Time Zone

Operation

Command

 

 

Set the local time

clock timezone zone_name { add

 

minus } HH:MM:SS

Restore to the default UTC time zone

undo clock timezone

 

 

By default, the UTC time zone is set.

Setting Daylight Saving Time

Use these commands to configure the start and end time of daylight saving time.