Maximum Link Distance Calculation

The following examples use the information provided in the previous pages to calculate the maximum allowable fiber optic link distance between two ports.

Example: 1700 Meter Fiber Link With Mechanical Splice

In the following example, two ONline concentrators are connected using 10BASE-FB Module ports.

Figure 2-1 shows an example of a 1700 meter fiber link with a mechanical splice using 62.5/125 fiber cable

.

Figure 2-1. 1700 Meter Fiber Link With Mechanical Splice

To calculate the maximum link distance:

1.Use Table 2-3 to determine the optical power budget for 62.5/125 cable (10.0 dB).

2.Use Table 2-6 to determine the worst case loss for a mechanical splice (1.0 dB).

2 - 12 ONline Ethernet 10BASE-FB Module Installation and Operation Guide

Page 36
Image 36
3Com 5102M-FBP, 5104M-FB1, 510M-FBP installation and operation guide Example 1700 Meter Fiber Link With Mechanical Splice