3.Subtract the known amount of fiber cable between the two transceivers:

1 km + 1 km + 1 km = 3 km (Rule 5)

4.The remainder is the maximum allowable distance of the link between Concentrators A and C:

4200 m - 570 m - 3000 m = 630 meters

5.Verify that the optical power budget is able to drive all the link distances in the example. Because all link distances are only 1 km or less, this is not a problem.

Example: Network with 8 Concentrators

Figure 2-7 shows a network with eight connected concentrators. Use this example to determine if the distances between transceivers are all within the 4200 meter maximum network diameter restriction for Ethernet networks.

100m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500m

 

 

 

1km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conc A

 

Conc E

 

Conc C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transceivers

 

 

 

 

 

 

500m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conc D

 

Conc E

 

500m

Conc F

400m

Conc G

 

 

 

 

 

 

 

 

 

Transceivers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1km

 

 

100m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conc H

 

 

 

Transceivers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100m

Note: All transceiver connections to concentrators are 100 meters

Figure 2-7. Network Configured With 8 Concentrators

2 - 20 ONline Ethernet 10BASE-FB Module Installation and Operation Guide

Page 44
Image 44
3Com 510M-FBP, 5102M-FBP, 5104M-FB1 Example Network with 8 Concentrators, Network Configured With 8 Concentrators