Table 4-2. Troubleshooting Using the Port Status LEDs (Continued)

LED State

Indication

Possible Cause

Corrective Action

 

 

 

 

 

5 Blinks

Invalid Data

Receive light

Verify that received

 

 

 

intensity too

optical power level is

 

 

 

high.

correct. Refer to

 

 

 

 

Chapter 2 (Link

 

 

 

 

Distances).

 

 

 

 

 

 

 

 

Connection

Unplug the

 

 

 

made to

connection. 10BASE-FL

 

 

 

10BASE-FL

is not compatible with

 

 

 

Module.

this 10BASE-FB

 

 

 

 

Module.

 

 

 

 

 

 

 

 

Bad fiber

Clean and reconnect

 

 

 

connections.

fiber (both ends).

 

 

 

 

 

 

 

 

Broken or

Check and fix RX fiber

 

 

 

cracked fiber.

link.

 

 

 

 

 

 

 

 

Bad remote

Try another port or

 

 

 

device.

replace device.

 

 

 

 

 

 

 

 

Bad 10BASE-FB

Replace the module.

 

 

 

Module.

 

 

 

 

 

6 Blinks

Low Light

Low light

Verify optical power

 

Received

received.

received is at low end

 

 

 

 

of optical power

 

 

 

 

budget by doing an

 

 

 

 

optical power

 

 

 

 

calculation. If value is

 

 

 

 

acceptable, disable low

 

 

 

 

light detection.

 

 

 

 

 

 

 

 

Legal

Disable low light

 

 

 

configuration

detection or enable

 

 

 

with acceptable

High power at remote

 

 

 

low light.

end.

 

 

 

 

 

4 - 6 ONline Ethernet 10BASE-FB Module Installation and Operation Guide

Page 84
Image 84
3Com 5102M-FBP, 5104M-FB1, 510M-FBP installation and operation guide 10BASE-FL