Installing and Operating the Module 3 -19
This display tells you the status of the specific port. It includes the
management and dip switch settings from the board.
The following command displays detai led information about the 10BASE-FB
Module in slot 8 of the concentrator.
ONline> show module 8 verbose [ENTER]
Port Display for Module 5104M-FB1:
Slot Module Version Network General Information
08 5104M-FB1 00x ISOLATED ETHERNET _2
5104M-FB1: ONline Ethernet 10BASE-FB Module
Network Dip Settin g: ETHERNET_1
Low Light Warning: DISABLED
Low Light Warning Dip Setting: DISABLED
This display tells you the status of the specific module. It includes the
management and dip switch settings from the board.
For more information on the SHOW comm ands, refer to the:
Appropriate ONline management module installation and operation
guide
ONline Management Commands Guide
Monitoring the Front Panel
The LEDs on the front panel of the 10BASE-FB Module allow you to monitor
the status of each port. The 10BASE-FB Module has 10 LEDs on the front
panel that allow you to monitor diagnostic, activity, and redundancy status
for each port. Figure 3-4 shows the locations of these indicators.