Setting Dip Switch S2

Dip switch S2 on the 10BASE-FB Modules have 10 switches. These switches allow you to:

Enable high or normal optical power for each port

Enable or disable any of the four ports

Enable or disable low light detection for the module

Table 3-4 lists the functions and settings for dip switch S2. Switch 10 is not used.

Table 3-4. Dip Switch S2 Settings

Switch

 

Label

Function

Factory

Switch Setting

 

Default

Off

On

 

 

 

 

 

 

 

 

 

 

 

1

P1

HIPWR

Port 1 High or

disable

disable

enable

 

 

 

Normal power

(normal)

 

 

 

 

 

 

 

 

 

2

P2

HIPWR

Port 2 High or

disable

disable

enable

 

 

 

Normal power

(normal)

 

 

 

 

 

 

 

 

 

3

P3

HIPWR

Port 3 High or

disable

disable

enable

 

 

 

Normal power

(normal)

 

 

 

 

 

 

 

 

 

4

P4

HIPWR

Port 4 High or

disable

disable

enable

 

 

 

Normal power

(normal)

 

 

 

 

 

 

 

 

 

5

P1

EN

Enable/disable

enable

disable

enable

 

 

 

Port 1

 

 

 

 

 

 

 

 

 

 

6

P2

EN

Enable/disable

enable

disable

enable

 

 

 

Port 2

 

 

 

 

 

 

 

 

 

 

7

P3

EN

Enable/disable

enable

disable

enable

 

 

 

Port 3

 

 

 

 

 

 

 

 

 

 

8

P4

EN

Enable/disable

enable

disable

enable

 

 

 

Port 4

 

 

 

 

 

 

 

 

 

 

Installing and Operating the Module 3 - 9

Page 65
Image 65
3Com 510M-FBP Setting Dip Switch S2, Dip Switch S2 Settings, Switch Label Function Factory Switch Setting Default