Troubleshooting Using the Activity LEDs

Under some conditions a port Activity LED may not light. Use the troubleshooting suggestions in Table 5-2 to help determine why the light is off, and to isolate the source of the problem.

Table 5-2. Troubleshooting Using the Activity LEDs

LED State

Possible Problem

Troubleshooting Solutions

 

 

 

Off

There is no traffic

None.

 

received from the

 

 

segments (normal).

 

 

 

 

 

Concentrator

Check the Controller Module

 

power is Off.

Power LEDs.

 

 

 

 

The Activity LED

Press the LED test button on the

 

has burned out.

Controller Module.

 

 

 

 

A Security Module

Connect the cable to a different

 

port is faulty.

port.

 

 

 

 

The module

Reinsert the Security Module. If this

 

connection to the

fails to correct the problem, try

 

backplane is bad.

another concentrator slot.

 

 

 

 

The Security

Try a different Security Module.

 

Module is faulty.

 

 

 

 

5 - 4 ONline 10BASE-T Security Module Installation and Operation Guide

Page 86
Image 86
3Com 5112M-TPLS Troubleshooting Using the Activity LEDs, LED State Possible Problem Troubleshooting Solutions