Network Video Server

User’s Manual

Event number can be mapped as a Sensor port and camera number. DI Open State :

This means that sensor is triggered and become open status from Normal close status. Select this when you use NC(Normal Close) type sensor.

DI Close State :

This means that sensor is triggered and become close status from Normal open. Select this when you use NO (Normal Open) type sensor.

Motion Detection :

By selecting this option, motion detection based event can be configured.

Camera Connected and Disconnected:

Camera status change by lost of camera signal can be recognized as an event Boot Finished :

Boot finish means Server reboot. Thus, when the server is rebooted, it can be recognized as an event.

Serial input :

FlexWATCHTM server can carry serial data along with video. When serial data from external serial device is activated, this can be recognized as a event.

Sensor state means when the sensor status is Open or closed. If you use NC( Normal

Close) type sensor and activate any action when sensor is open, you need to select [Open State] and vice versa when you use NO (Normal Open) type of sensor.

)Please check out sensor type connected to FlexWATCHTM server

87

Seyeon Tech Co., Ltd

 

- INTPLUS [2005] -

Page 87
Image 87
3Com FlexWATCH 3110 user manual DI Close State, Motion Detection, Camera Connected and Disconnected