32
ID Memory contents.
The scale ID memory can contain unit weights with tare
weights and comparator limits, or just unit weights alone.
00ID memory contains the unit weight only.
You select which data to be stored by keying in a
0 or 1 for the data: tare weight or comparator
limits.
Example: Key in 1 0 to display 10, ID memory
contains the unit weight and comparator limits.
F-02-X ACAI Operation & Min. Unit Weight
ACAI Mode When Unit Weight entered by Sample Pieces.
0ACAI is disabled.
1ACAI automatic Operation.
2ACAI Manual Mode (using the ENTER key).
ACAI Mode When Unit Weight entered by Keyboard or ID.
0ACAI is disabled.
1ACAI Manual Mode (using the ENTER key). This setting
works when f-02-01 setting is not “0”.
2ACAI Automatic obeys f-02-01 setting.
Minimum Unit Weight. (1d=1 weighing display division)
The factory setting may be different for some countries.
01/5 d
11/100 d
f-02-01f-02-02f-02-03f-01-05
00
Comparator limits
Tare Wei
g
ht