f-04-05

‰Auto power-off

0

Auto power-off disabled.

1

Auto power-off enabled.

 

 

‰“f-04-06” is for factory use and should be “0”.

F-05-X Comparator

f-05-01

f-05-02

f-05-03 f-05-04

f-05-05

‰Comparator Mode.

0

Comparator OFF.

1

Compare all data.

2

Compare stable data.

3

Compare all data except when near ZERO*.

4

Compare stable data except when near ZERO*.

5

Compare all positive data except when near ZERO*

6

Compare stable positive data except when near ZERO*.

 

 

*“near ZERO” means between –4d and +4d of weight data.

‰Data to Compare – Count or Weight

0

Compare count data.

1

Compare weight data.

 

 

‰Upper Limit.

0

Enter via the 10-key pad.

Use the . key to “set minus value.

 

‰Lower Limit.

0

Enter via the 10-key pad.

Use the . key to set minus value.

 

‰A Beeper With Comparator Results.

These are beeps for the comparator, not for the key operation.

000

 

 

All Comparator Beepers are OFF.

 

 

 

 

 

 

 

 

 

 

Example:

010

000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

= Beeper OFF

The OK beep sounds – HI & LO doesn't

 

 

 

 

 

 

 

 

HI

 

LO

 

1

= Beeper ON

sound. The scale will beep continuously

 

 

 

 

 

OK

 

 

 

when display meets OK condition.

 

 

 

 

 

 

 

 