F-06-X RS-232C Data Output

F-06-X requires OP-03 or OP-04 RS-232C interface.

f-06-01

f-06-02

‰ Data Out Mode

0

Key Mode: Data is sent by pressing the

PRINT

key.

+ Command Mode.

 

1

Stream Mode: Data is sent continuously.

Command Mode cannot be used.

 

2

Auto-Print Mode A: Data is sent if the weight display is stable

at +5d (weighing display division) and above.

 

+ Command Mode.

3

Auto-Print Mode B: Data is sent if the weight display is

stable, at ±5d (weighing display division) and above/below.

 

+ Command Mode

4

Command Mode Only.

5

To use as Bar Code Reader Interface.

6

UFC format with Key Mode (see setting “0”).

7

UFC format with Auto-Print Mode A (see setting “2”).

8

UFC format with Auto-Print Mode B (see setting “3”).

‰Data to be Sent.

0100 Count data sent.

Unit

ID Weight

0000

Weight

PCS(count)

You select which data to be sent by keying in a

0or 1 for the data: ID no., PCS (count), weight or unit weight.

Example: Key in 1 1 0 0 to display 1100, this setting would send only the ID number and the count.

f-06-03

‰Data Format

0

Format for AD-8121 MODE 1.

No difference between “0”

 

 

and ”1” when used with the

1

Format for AD-8121 MODE 3.

UFC format.

2

Format for general apparatuses, computers, etc.

f-06-04

‰Baud Rate

0

2400 bps.

 

 

1

4800 bps.

 

 

2

9600 bps.

 

 

35

Page 37
Image 37
A&D HC-3Ki, HC-15Ki, HC-30Ki, HC-6Ki manual 06-01 06-02, 06-03, 06-04, RS-232C Data Output