AMT Datasouth 4500 Series manual Setting the Printing Method, Programming the Print Method

Models: 4500 Series

1 94
Download 94 pages 29.62 Kb
Page 41
Image 41

Media Settings

Setting the Printing Method

The CodeWriter 4500 Series Printers offer Thermal Transfer and Direct Thermal print methods. Thermal Transfer printers use a ribbon which transfers ink to the label during the printing process. Direct Thermal printers use specially treated labels that darken in the heated areas while printing.

Printer models with thermal transfer capability will print using thermal transfer or direct thermal media. Direct thermal printer models will only print using direct thermal media.

Programming the Print Method

ONLINE

1.

Press the

PAUSE

key. This takes you to the off-line menu.

 

 

 

 

 

MENU

2.

When Interface Status Off-Lineis displayed, press the

key. This

 

will take you the to the listing of sub-menus.

 

 

 

MENU

 

 

 

3.

Press the

 

key until the Label Parameters option is displayed.

 

 

ITEM

 

 

 

4.

Press the

FEED

key. Media Type is the first parameter displayed. The two

 

options for this parameter are Direct Thermal and Thermal Trans. Press

 

the

or CANCEL key to change the option. Complete the selection

 

 

 

ENTER

 

 

 

process by pressing the PRINT key. An asterisk (*) will appear in front of

 

the selected option to indicate the value has been set.

 

 

 

ONLINE

 

 

 

5.

Press the

PAUSE

key. If the Media Type parameter was changed, the

 

 

 

 

 

ENTER

 

display will read ENTER to save new defaults. Press the

PRINT key to

 

save these values. The display will then read Interface Status Online.

 

 

 

 

ONLINE

 

6.

To verify the settings are correct, press the

PAUSE key. With the Interface

 

 

 

ITEM

 

 

 

Status Off-Linedisplayed, press the FEED

key. If the label feeds

 

 

 

 

ONLINE

 

 

correctly put the printer back On-line by pressing the PAUSE

key. If while

 

feeding a label error messages related to the ribbon are displayed, turn to

this manual’s Troubleshooting Guide for information on adjusting the ribbon sensor sensitivity.

31

Page 41
Image 41