Advanced Features

Print Darkness Control

CodeWriter 4500 Series Printers shipped with this manual4 will contain a new Print Darkness control method. This method replaces the print settings method that involved a Contrast and Preheat setting. The Operator Panel includes access to these former methods to service current customers obtaining satisfactory print quality with those settings. Customers desiring to use this previous method may use the following procedure.

New Customers not obtaining satisfactory results with the Print Darkness method should contact their Datasouth representative for additional assistance.

Setting Contrast and Preheat

Use the following procedure the program the printer’s Contrast and Preheat parameter values:

ONLINE

1.

Press the

PAUSE

key. This takes you to the off-line menu.

 

 

 

 

 

MENU

2.

When Interface Status Off-Lineis displayed, press the

key. This

 

will take you the to the Print Parameters menu.

 

 

 

ITEM

 

 

3.

Press the

FEED

key until ENTER to Select Expert Settings is displayed.

ENTER

4.Press the PRINT key.

5.Print Cont. is the first parameter displayed. Press the or CANCEL key to change the Contrast value.

NOTE: When changing values using the or CANCEL keys, a single key press will change the value by one unit. If the key is pressed and held in, the value will change by 10 units.

6.Press the or

ITEM

FEED

CANCEL

key. Pre-Heatis the next parameter displayed. Press the key to change the Preheat value.

ONLINEONLINE

7. Press the PAUSE

key, followed by the PAUSE

key. The display will read

 

 

ENTER

ENTER to save new defaults. Press the

PRINT key to save these values.

MENU

 

Or Press the

key to return to the Print Parameters menu.

4Firmware Revision - 4505/4505+: 109225 Revision A or later, 4510: 109063 Revision D or later.

83

Page 93
Image 93
AMT Datasouth 4500 Series manual Print Darkness Control, Setting Contrast and Preheat, Enter to save new defaults . Press