Figure 4. PCI Addressing for 24-bit and 16-bit Memory Blocks in 24-bit Access (BAR2) ModeFigure 5. PCI Addressing for 24-bit and 16-bit Memory Blocks in 16-bit Access (BAR3) Mode.
BYTE3 BYTE2 BYTE1 BYTE0
PCI DWORD
DSP Word AddressPCI Byte Address
UNUSED
UNUSED
0x0000
0x3FFF
0x4000
0x7FFF
0x0 0000
0x0 FFFC
0x1 0000
0x1 FFFC
16K x 24-bit Block
16K x 16-bit Block
BYTE3 IS ALWAYS UNUSED.
BYTE0 IS UNUSED BY 16-BIT
MEMORY LOCATIONS.
ALLOWED BYTE ENABLES:
C/BE = 0000
C/BE = 1000
BYTE3 BYTE2 BYTE1 BYTE0
PCI DWORD
DSP Word AddressPCI Byte Address
UNUSED
0x0000
0x3FFF
0x4000
0x7FFF
0x0 0000
0x0 7FFE
0x0 8000
0x0 FFFE
16K x 24-bit Block
16K x 16-bit Block
UNUSED
Data Word NData Word N+1
ALL BYTES ARE USED.
ALLOWED BYTE ENABLES:
C/BE = 1100
C/BE = 0011
C/BE = 0000
Data Word N