PowerAudibleAlarm

Silences the audible alarm for a current power supply failure. The alarm will be activated on the next power failure.

Immediate command: PowerAudibleAlarm disabled

RAID5ClearDataStatus

Displays the status of RAID5 Clear Data processing. S represents the sled number, D represents the drive number. Applies to RAID5 only

Set syntax: RAID5ClearDataStatus

RAIDRebuildStatus

Displays the RAID1, RAID 5 or RAID 10 Rebuild Status Summary. If no RAID groups are defined, the header information is displayed with no data. The status summary contains the RAID1, RAID 5 or RAID 10.The RAIDRebuildStatus command has no effect on the state of any rebuild in progress.

Member index and the following fields in tabular form:

Status : OK, DEGRADED, IN PROGRESS, or

FAULTED

Sled Number : Location of the sled

Current LBA: Logical block currently being rebuilt

Maximum LBA: Last logical block to be rebuilt

Status OK: the RAID1 Mirror is in sync and no rebuild activity is occurring. The Current LBA, Maximum LBA and percentage complete values are not displayed.

Status Degraded: the RAID1 Mirror is out of sync and is waiting to be rebuilt.

Status In Progress: the RAID1 Mirror is out of sync and a rebuild is occurring on the respective drive.

Status Faulted: the RAID1 Mirror is out of sync and an error occurred in an attempt to synchronize the drives in the RAID 1 group.

SerialNumber

View the board serial number, a 10-character field. The first four alphanumeric characters are an abbreviation representing the product name. The remaining six digits are the individual unit’s number.

Get syntax: get SerialNumber

SledFaultLED

Changes the state of the selected sled LED to the indicated state. Choose the sled number, 1-12,or all, turn on or off

Default: off

Set syntax: set SledFaultLED [ all 1 2 3 4 5 6 7 8 9 10 11 12] [ on off]

SMARTData

Displays the current SMART (Self-Monitoring Analysis and Reporting Technology) data for the specified drive.

Immediate command: SMARTData [sled#] [drive #]

TapeDriveInfo

Displays information about the named Tape Drive including LUN, Tape Volume ID and state of the tape drive.

Get syntax: TapeDriveInfo [tape drive #]

TapeVolumeInfo

Displays information about the named Tape Volume including Volume ID, LUN, Virtual Disk ID, Partition ID, Total capacity and percentage of capacity used.

Get syntax: TapeVolumeInfo [tape volume #]

Temperature

Returns the current internal temperature of this Diamond Storage Array in degrees Celsius. The value is read only.

Get syntax: get Temperature

VirtualDriveInfo

Displays the named Virtual Drive definitions.

Get syntax: VirtualDriveInfo [activeplanned] [Virtual Drive ID]

ZoneInfo

Displays the named zones’ definitions. Information about the Active Zone Configuration is the default; if you want information about the Planned Zone Configuration, type ZoneInfo Planned zone_name.

Zone syntax: ZoneInfo [Planned] [zone_name] [all]

ZoneState

Changes the specific state of a zone. The ZoneState command must be entered as enabled to activate the zone before using the ZoneCommit command (which makes the Planned Zone Configuration the Active configuration).

Default: disabled

Set syntax: ZoneState zone_name [enableddisabled]

Get syntax: ZoneInfo

40 CLI: diagnostics

Page 51
Image 51
ATTO Technology VT-Class PowerAudibleAlarm, RAID5ClearDataStatus, RAIDRebuildStatus, SerialNumber, SledFaultLED, SMARTData