Appendix F Product Safety

Safe handling of the Diamond-VT will help protect its components as well as the people working with them.

The Diamond-VT is heavy (92 pounds for the floor model, 86 pounds for the rack mount system). Two people will be needed to move it safely.

Mechanical, shock and energy hazards are present through the system if one or more of the modules is removed. There are no operator- serviceable components inside the unit except those indicated in Hardware Maintenance on page 67 and Hot Swap Operating Instructions on page 69of this manual.

CAUTION

All modular components must be replaced by qualified personnel only.

This equipment must be connected to a protective earth ground in accordance with the instructions provided in this guide. Improper grounding may result in an electrical shock.

This unit is designed to only have inside communication lines connected to it (no lines outside the building proper).

The Diamond-VT must be provided with adequate air flow. To reduce the risk of damage,

the ambient temperature of the inlet air should not exceed 40oC.

Service personnel must follow proper grounding methods when working with or around the system because of the Diamond-VT’s electrostatic sensitive components. Use a static wriststrap when handling any components from the Diamond-VT.

Safety compliances

UL 1950 3rd Edition

CSA 22.2 No. 950-95

LEDs and fibre GBIC are Class 1 Laser Rated

• When the power supply green LED is on, the power source is fully operational, delivering power to the

system. The only way to

On Stand-bycompletely disconnect from the system is to remove the

AC power cord from the back of the unit from both power supply inputs. The switch on the power supply is only a standby switch and does not disconnect the AC from the system.

EMC specifications

EN 55022: class A

EN 50204 RF Immunity 900 MHz Pulse

EN 61000-4-8 Magnetic Immunity

EN 61000-4-2: ESD

EN 61000-4-3: Radiated Immunity

EN 61000-4-4: EFT

EN 61000-4-5: Surge

EN 61000-4-6: Conducted Immunity

EN 61000-4-11: Voltage Dips and Interruptions

Radio and television interference

WARNING

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.