Figure 4-5 Garretson KN Fuel Valve

Outlet

Mount

Primer (Optional)

Lock−Off

Adjustment

Inlet

Mount

Service

The KN should be periodically checked for leakage past the valve seat and the vents on the cover kept clean and free of obstructions. If the KN needs service we suggest you take it to a qualified serviceman. If that help is not available Garretson will furnish you a list of repair shops with the proper service information.

Installation

The KN should be mounted as close to the carburetor as possible with the arrow on the cover pointing up and the diaphragm in a vertical position. This helps to minimize the effects of gravity on diaphragm travel. This unit should also be placed for easy access to the primer if provided. There are two sets of mounting holes provided. either set of mounts will adequately support the KN. The bottom set of holes has a 1 3/4” bolt spacing for use with all Garretson universal mounting brackets. The mounting bosses on the cover are spaced (5 3/4”) for 5/16 bolts.

Before installing the fuel supply line, be sure that the gas pressure is no more than the maximum inlet pressure shown on the front of the KN. If the pressure is greater, leakage could result in a fire hazard and or hard starting. The piping to the inlet should be of sufficient size to allow full flow to the KN. This is very important in natural gas installations as any restrictions can affect engine performance. If a solenoid is used ahead of the KN in the low− pressure line, it should have an orifice at least as big as the orifice in the KN. Flexible piping to the inlet should be used to prevent cracking from vibration if the KN is mounted on the engine or other vibrating surface.

Note: Thread sealing compound should be used on all pipe thread fittings between the KN and the fuel supply tank, being careful not to get any inside the inlet or fittings. Excess compound could collect on the seat and orifice and cause hazardous leakage, resulting in poor performance. After piping is complete, turn on the gas and use a soap solution to check all fittings for leaks.

If an electric solenoid primer is used, follow the wiring and adjusting instructions furnished separately. kit by connecting into a pressure line at a reduced pressure, call us. The KN outlet is 3/8 NPT and if an outlet fitting has not been provided, select and insert a suitable vapor fitting taking care not to allow any chips or dirt to enter the outlet. Use of street ells or conventional pipe fittings in the fuel line between the KN and the carburetor is not recommended as they may restrict the flow of fuel.

When installation of a properly sized fuel hose between the KN and carburetor is completed, if you are installing a complete conversion return to the instructions. For field replacement applications the unit is ready for service.

4-10 Operation

MN2415

Page 40
Image 40
Baldor AE11, AE10, AE25, AE8 manual Garretson KN Fuel Valve, Service

AE8, AE25, AE10, AE11 specifications

Baldor Electric Company has long been a trusted name in the manufacturing of electric motors and drives. Among their impressive lineup of products, the AE series, which includes the AE11, AE25, AE10, and AE8 models, stands out for their innovative features and robust performance, making them suitable for a variety of industrial applications.

The Baldor AE11 is designed with high efficiency in mind, ensuring that it consumes less energy while delivering optimal performance. This motor features a robust design that enhances durability and reliability, making it ideal for heavy-duty applications. The AE11 also incorporates advanced thermal management technology, ensuring that the motor remains cool even during prolonged use. Its compact size allows for easier integration in tight spaces, making it a versatile choice for many machinery types.

The AE25 model takes performance a step further with its enhanced power output and torque capabilities. This model is built for demanding environments and is engineered to reduce vibration and noise, providing a smoother operational experience. The AE25 also features built-in thermal protection, which automatically shuts down the motor in case of overheating, thereby safeguarding the equipment and reducing maintenance costs.

For those needing a more compact solution, the AE10 offers a balance of power and size. This electric motor is designed with a lightweight yet sturdy build, providing a perfect fit for smaller machines without sacrificing performance. The AE10 is equipped with high-energy efficiency ratings, contributing to lower operational costs and reduced environmental impact. Additionally, it supports various mounting options, enhancing its adaptability for different applications.

Lastly, the AE8 model is a true powerhouse for applications where space is at a premium. It features a minimalist design while still delivering reliable performance. The AE8 is optimized for energy efficiency, boasting a streamlined motor design that minimizes wasted energy. With its quiet operation and low maintenance requirements, this model is ideal for environments where noise reduction is essential.

In summary, the Baldor AE series—including the AE11, AE25, AE10, and AE8—shows a real commitment to efficiency, durability, and versatility. Each model is tailored to meet specific industry needs, whether for demanding heavy-duty applications or compact, energy-efficient setups. With their innovative technologies and engineering excellence, Baldor motors continue to set the standard in the electric motor industry.