Display

Trip Message and Meaning

Possible Reason for Trip

 

 

Motor loading too great

 

 

FIXED BOOST level set too high

 

DC LINK RIPPLE

Supply imbalance in a 3–phase system

 

A dc link ripple alert

Poor supply regulation in a 1–phase system

 

CURRENT LIMIT

See OVERCURRENT above

 

Software overcurrent trip

 

 

TERMINAL 3 OVERLOAD

AIN2 overload – overcurrent applied in Current

 

 

mode

 

TERMINAL 4 OVERLOAD

+10V REF overload warning – 10mA maximum

 

TERMINAL 5 OVERLOAD

AOUT overload – 10mA maximum

 

TERMINAL 9 OVERLOAD

DIN3 overload – 20mA maximum

 

TERMINAL 10 OVERLOAD

DOUT2 overload – 20mA maximum

 

Product Code Error

Switch unit off/on. If persistent, return unit to

 

 

factory

 

Calibration Data Error

Switch unit off/on. If persistent, return unit to

 

 

factory

 

Configuration Data Error

 

General Failures

Problem

Possible Cause

Remedy

Inverter will not power–up

Fuse blown

Check supply details, fit correct fuse.

 

 

Check Product Code against Model

 

 

No.

 

Faulty cabling

Check all connections are

 

 

correct/secure.

 

 

Check cable continuity

 

 

 

Inverter fuse keeps blowing

Faulty cabling or

Check for problem and rectify before

 

connections wrong

replacing with correct fuse

 

Faulty Inverter

Contact Eurotherm Drives

 

 

 

Cannot obtain power–on

Incorrect or no supply

Check supply details

state

available

 

 

 

 

Motor will not run at

Motor jammed

Stop the Inverter and clear the jam

switch–on

 

 

 

 

 

Motor runs and stops

Motor becomes jammed

Stop the Inverter and clear the jam

 

 

 

 

Open circuit speed reference

Check terminal

 

potentiometer

 

 

 

 

5–2 Troubleshooting

MN735

Page 45
Image 45
Baldor MN735 manual General Failures, DC Link Ripple