Table 4-1 Parameter Definitions Continued

Display

Parameter

Description

Range

Factory

 

 

 

 

Setting

 

RELAY INVERT

True =Inverts the input signal.

0= False

0

 

 

 

1= True

 

 

RELAY VALUE

The output signal that represents the OP31

0= False

0

 

~

choice.

1= True

 

 

 

SET::TRIP Menu

 

 

 

DISABLE LOOP

Disables LOST I LOOP trip (4-20mA)

0= Trip Enabled

1

 

 

 

1= Trip Disabled

 

 

AIN2

Disables the overload trip (Terminal 3)

0= Trip Enabled

0

 

OVERLOAD

 

1= Trip Disabled

 

 

DISABLE

Disables STALL trip

0= Trip Enabled

0

 

STALL

 

1= Trip Disabled

 

 

DISABLE

Disables the motor thermistor trip

0= Trip Enabled

0

 

MOTOR

 

1= Trip Disabled

 

 

OVERTEMP

 

 

 

 

 

SET::SETP Menu

 

 

 

Inverse Time

Disables the inverse time trip

0= Trip Enabled

1

 

 

 

1= Trip Disabled

 

 

Display

Disables the display (keypad) trip

0= Trip Enabled

0

 

(Keypad)

 

1= Trip Disabled

 

 

Jog Accel Time

As P4, for Jog

0.0 to 3000.0s

1.0

 

Jog Decel Time

As P5, for Jog

0.0 to 3000.0s

1.0

 

Ramp Type

Selects the ramp type

0=LINEAR

0

 

 

 

1=S

 

 

S Ramp Jerk

Rate of change of acceleration of the curve in

0.01 to 100.00s3

10.00s3

 

 

units per second3

 

 

 

S Ramp

When True and the S Ramp is selected, forces

0=FALSE

1

 

Continuous

a smooth transition if the speed setpoint is

1=TRUE

 

 

 

changed when ramping. The curve is controlled

 

 

 

 

by the S Ramp Jerk parameter.

 

 

 

 

When False, there is an immediate transition

 

 

 

 

from the old curve to the new curve

 

 

 

Skip

The center frequency of skip band 1 in Hz

0.0 to 240.0 Hz

0.0

 

Frequency 1

 

 

 

 

Skip Frequency

The width of skip band 1 in Hz

0.0 to 60.0 Hz

0.0

 

Band 1

 

 

 

 

Skip

The center frequency of skip band 2 in Hz

0.0 to 240.0 Hz

0.0

 

Frequency 2

 

 

 

 

Skip Frequency

The width of skip band 2 in Hz

0.0 to 60.0 Hz

0.0

 

Band 2

 

 

 

 

Auto Restart

Determines the number of restarts that will be

0 to 10

0

 

Attempts

permitted before requiring an external fault

 

 

 

 

reset

 

 

 

Auto Restart

The delay between restart attempts for a trip

0.0 to 600.0 s

10.0s

 

Delay

included in Auto Restart Triggers and Auto

 

 

 

 

Restart Triggers+. The delay is measured from

 

 

 

 

all error conditions clearing

 

 

 

Auto Restart

Allows Auto Restart to be enabled for a

0x0000 to 0xFFFF

0x0000

 

Triggers

selection of trip conditions. Refer to Section 5

 

 

4–10 Start–Up and Operation

MN735

Page 39
Image 39
Baldor MN735 manual Relay Invert