Section 6

Specifications & Product Data

General Specifications:

 

 

 

 

 

Enclosure:

 

Open Type (Protected Chassis)

 

Enclosure rating:

Europe

IP20

 

 

 

North America / Canada

Chassis/IP20

 

 

Mounting method:

 

Panel mount or DIN rail mounting (35mm).

Enclosure emissions:

 

Enclosure provides 15dB attenuation to radiated

 

 

emissions between 30–100MHz. It must also

 

 

require a security tool for opening.

 

Horsepower:

 

1/3–2 HP

@ 230VAC, 1 Phase

 

 

 

3–5 HP

@ 230VAC, 3 Phase

 

 

 

1/2–10 HP @ 460VAC, 3 Phase

 

Voltage Range: 230 VAC Models

198-264 VAC 1φ

60 Hz / 198-264 VAC 1φ

50 Hz

460 VAC Models

198-264 VAC 3φ

60 Hz / 198-264 VAC 3φ

50 Hz

 

 

342-506 VAC 3φ

60 Hz / 342-506 VAC 3φ

50 Hz

Input Line Impedance:

 

1%

 

 

 

Service Factor:

 

1.0

 

 

 

Duty:

 

Continuous

 

 

 

Ambient Operating Temperature:

0 to +40 ° C with linear derating to 50 ° C

 

 

 

(maximum).

 

 

Cooling:

 

Forced air included when required.

 

Rated Storage Temperature:

– 25 ° C to +55 ° C

 

Humidity:

 

10 to 85% RH @ 40 ° C Non-Condensing

 

Altitude:

 

Sea level to 3300 Feet (1000 Meters)

 

 

 

Derate 1% per 330 Feet (100 Meters) above 3300

 

 

Feet

 

 

 

Shock:

 

1G

 

 

 

Vibration:

 

0.5G at 10Hz to 60Hz

 

Climatic conditions:

 

Class 3k3, as defined by EN50178 (1998)

 

Safety:

Europe

EN50178 (1998), when installed inside suitable

 

 

enclosure.

 

 

 

North America / Canada

UL508C

 

 

 

Overvoltage Category

Category III (3 phase power), Category II (1 phase

Pollution Degree

Logic power)

 

 

Pollution Degree 2

 

EMC Compliance:

Immunity:

EN50082–1 (1992), EN50082–2 (1992),

 

Radiated Emissions:

EN61800–3

 

 

 

 

EN50081–1(1992) and EN61800–3 when mounted

 

 

inside the specified enclosure. Control and motor

 

 

cables must be screened and correctly installed

 

 

with shielded couplings where they exit the

 

 

enclosure. Control 0V must be connected to

 

 

protective earth/ground.

 

Conducted Emissions:

 

EN50081–1(1992), EN61800–3 unrestricted

 

 

distribution, maximum motor cable length is 25m.

MN735

Specifications & Product Data 6–1

Page 46
Image 46
Baldor MN735 manual Section Specifications & Product Data, General Specifications