DON'T install the scanner inside of the recommended compass safe distances of any

navigation instruments such as the magnetic compass and the chronometer. The compass

safe distances are as follows:

2 kW radar

STD 2.3 ft (0.7 m)

 

STEER 1.6 ft (0.5 m)

 

 

4 kW radar

STD 6.5 ft (2.0 m)

 

STEER 5 ft (1.5 m)

 

 

6 kW radar

STD 7.5 ft (2.3 m)

 

STEER 5.7 ft (1.75 m)

 

 

10 kW radar

STD 7.9 ft (2.4 m)

 

STEER 6 ft (1.8 m)

 

 

25 kW radar

STD 7.9 ft (2.4 m)

 

STEER 6 ft (1.8 m)

 

 

6.5Northstar 8000i 8 Port Network Linker

Northstar 8000i 8 Port Network Linker NS004721

Description

The Northstar 8000i 8 Port Network Linker is a marinized 100 base ethernet switch.

Place in 8000i System

The Northstar 8000i 8 Port Network Linker is used to connect up to eight (8) Northstar 8000i network devices. Use the Linker when joining three (3) or more network devices together. You can use a crossover cable when joining just two (2) network devices together. Connect more than one linker together to give 16, 24 etc ports