Breville BES860XL manual PERFECTING YOUR SKILLS - Single Wall Filters continued, Manual Function

Models: BES860XL

1 116
Download 116 pages 48.61 Kb
Page 40
Image 40
RESETTING DEFAULT VOLUMES

PERFECTING YOUR SKILLS - Single Wall Filters (continued)

RESETTING DEFAULT VOLUMES

MANUAL FUNCTION

STEP 10 – EMPTYING THE PORTAFILTER

To reset the machine to the default one and two shot pour quantities, press and hold the PROGRAM button until the machine beeps three times. Release button. This indicates the machine has returned to its original default settings.

NOTE: Default settings: one cup MANUAL FUNCTION pour is approximately 1 oz. Two cups STEP 10 – EMPTYING THE PORTAFILTERManual background is approximately 2 oz.

The Manual function over-rides the preset shot size for one time only. It does not save the shot size like in programming mode.

Press and hold the one cup Manual background or two cup Manual backgroundManual background button. Release the button once sufficient

espresso has flowed into the cup.

ssRemove the portafilter from the group head by rotating the portafilter to the left until it releases.

ssTo empty the used grounds, turn the portafilter upside down in a bin and gently knock out the grounds. Used grounds should be thrown away with domestic waste. Discarding of used grounds in a sink can cause drains to become blocked.

ssWith the filter still in place, hold the portafilter underneath the group head, press and hold

down the one cup Manual background button to release hot water. Rinse the portafilter until water runs clear.

ssInsert the portafilter back into the group head to dry out and keep warm.

WARNING: THE METAL PARTS OF THE

PORTAFILTER WILL BE VERY HOT.

40

Page 40
Image 40
Breville BES860XL manual PERFECTING YOUR SKILLS - Single Wall Filters continued, Resetting Default Volumes, Manual Function