7-20. Adjusting the home position

7. ADJUSTMENT

7-20. Adjusting the home position

7-20-1. Work clamp lift home position

1

Turn the pulley to set the needle to the needle up stop position.

 

 

2

 

While pressing

the

keys simultaneously, turn on

 

 

the power switch.

keys until the model name is

 

 

*

Keep pressing the

 

 

 

displayed and the buzzer beeps once.

 

 

"orG" will flash in the PROGRAM No. display and the

 

 

 

offset value (default: 0) will be displayed in the menu

 

 

 

display.

 

 

 

TEST indicator and THREAD/CLAMP indicator light

 

 

5205Q 4443Q 4421Q

3

Press the RESET key.

 

 

 

 

• Home position detection will be carried out, and the work clamp will stop at the

 

currently-registered home position.

 

 

 

 

* If you press the RESET key for 2 seconds or more at this time, the offset value will be reset

 

to “

0 ”.

 

 

 

4

<Solenoid specifications>

Press the or

key to change the offset value (-999

 

 

to 999) so that the work clamp lifter plate (1) moves to the

 

 

position where it starts to lower.

• The work clamp lifter plate (1) will move in conjunction with the setting value.

Touch the bottom of the work clamp lifter plate and check

 

the position where it starts to lower.

5206Q 5208Q

 

 

<Pneumatic specifications>

Remove the motor cover, align the index marks of the

work clamp cam gear (2) and the work clamp driving gear

 

(3) to the center line, and then press the or key to

 

change the offset value (-999 – 999).

Index mark

• The work clamp driving gear (3) will move in

conjunction with the setting value.

 

 

5207Q 5208Q