3-11. Updating the control program

3. READING / WRITING DATA

3-11. Updating the control program

1

 

Select the [r 7] data read/write mode.

 

 

4585Q

 

 

 

2

 

Press the R/W key.

 

 

[-SyS] will be displayed for a certain amount of time, and

 

 

then the display will change to [ vEr], and after that the

 

 

version number of the control program that is stored on

 

 

the CF card will be displayed.

 

 

 

3

 

Press the R/W key.

 

 

[ P] will flash in the PROGRAM No. display and the

 

 

control program will be updated.

 

 

NOTE:

 

 

If the filename and folder name for the control program

 

 

are incorrect, error [E421] will be displayed.

 

5060Q

 

 

 

 

4

 

When [ End] is displayed, the process is complete.

 

 

Turn off the power switch, remove the CF card, and then

 

 

close the cover of the CF slot.

 

 

NOTE:

 

 

Version updating may take about 3 10 minutes.

 

 

(The time taken will vary depending on the

 

 

manufacturer and storage capacity of the CF card

 

 

being used. )

 

4581Q

Never remove the CF card or turn off the power

 

switch while reading of the CF card is in progress.

<Restoring the control program if an error occurs during updating>

If the version updating did not complete normally, such as because of a power outage, the sewing machine will not operate correctly.

If this happens, restore the control program by the following procedure.

1. Insert the CF card containing the control program data into the CF card slot.

2. Turn on the power switch. The operation panel will switch off and the version updating will be carried out.

3. When the initial screen turns back on, the updating is complete. Turn off the power switch, remove the CF card, and then close the cover of the CF slot.