9. TABLE OF ERROR CODES

 

 

 

 

 

 

Communication and memory-related errors

 

 

Code

Cause and remedy

 

 

 

Connection communication error with power supply motor P. C. board detected when power was turned on.

 

 

E401

Turn off the power, and then check that connector P6 on the power supply motor P.C. board and connector P17

 

 

 

on the main P.C. board are properly connected.

 

 

E402

Communication error with programmer detected when power is turned on.

 

 

Turn off the power, and then check that connector P7 on the main P.C. board is properly connected.

 

 

 

 

 

E403

Connection error with PMD P. C. board detected when power was turned on.

 

 

Turn off the power, and then check that connector P1 on the PMD P.C. board is properly connected.

 

 

 

 

 

E410

Communication error with main P. C. board detected.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

 

Communication error with power supply motor P. C. board detected.

 

 

E411

Turn off the power, and then turn it back on again.

 

 

 

Check if the fuse (F4) is blown.

 

 

E412

Communication error with programmer detected.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

E413

Communication error with PMD P. C. board detected.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

E420

No CF card is inserted.

 

 

E421

Program contents are incorrect and cannot be used, or no data.

 

 

Check that the CF card or floppy disk contains data with this program number.

 

 

 

 

 

E422

Error occurred while reading the CF card or floppy disk.

 

 

Check the data on the CF card or floppy disk.

 

 

 

 

 

E424

Insufficient free space on CF card.

 

 

Use a different CF card.

 

 

 

 

 

 

Error occurred while writing to the CF card or floppy disk.

 

 

E425

Use the specified type of CF card.

 

 

 

Check if the floppy disk is write-protected and if it has enough free space.

 

 

E426

R/W key has not been pressed.

 

 

Press the R/W key to load the data.

 

 

 

 

 

 

CF card or floppy disk does not contain any data with this program number.

 

 

E427

Check the program number.

 

 

 

Data that has already been loaded into internal memory can be used without having to press the R/W key again.

 

 

E430

Data cannot be backed up to main P.C. board.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

E440

Data memory error on main P.C. board.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

E450

Model selection cannot be read from the machine head memory.

 

 

Turn off the power and check that connector P3 on the power supply motor P.C. board is properly connected.

 

 

 

 

 

E451

Data cannot be backed up to machine head memory.

 

 

Turn off the power, and then turn it back on again.

 

 

 

 

 

E452

Machine head memory is not connected.

 

 

Turn off the power and check that connector P3 on the power supply motor P.C. board is properly connected.

 

 

 

 

 

 

Internal memory is full and copying is not possible.

 

 

E474

Clear the sewing data, or change the settings so that sewing data is not copied to internal memory when it is

 

 

 

loaded (memory switch No. 466 = ON).

 