<Pneumatic specifications, 2 pedal standard operations>

2. FUNCTION SETTINGS

<Pneumatic specifications, 2 pedal standard operations>

Operating mode

Memory switch setting

Work clamp operation After home position After sewing start detection

 

Automatic lift

Automatic lift

Work clamp lifts automatically

Dropped

 

and drops when the work

 

 

 

Automatic lift

clamp switch is depressed.

Dropped

 

Dropped

 

 

 

 

 

Work clamp rises while work

Dropped

Dropped

clamp switch is depressed

 

 

 

 

 

Work clamp switch

Automatic lift

Automatic lift

1st step: Both left and right

 

Dropped

work clamps drop

 

2nd step: Intermittent presser

 

Automatic lift

foot drops

Dropped

 

Dropped

Lifting is simultaneous

 

Work clamp drop sequence at

Automatic lift

Automatic lift

 

work clamp switch 1st and

Dropped

 

2nd steps alternates each

 

 

 

Automatic lift

time an article is sewn.

Dropped

Initially right left

Dropped

 

 

 

002

Work clamp drop sequence selection

0:Left and right simultaneously

1:Left Right

2:Right Left

050

057

058

 

 

 

3

ON

OFF

 

 

 

3

ON

ON

 

 

 

3

OFF

OFF

 

 

 

3

OFF

ON

 

 

 

4

 

 

 

5

ON

OFF

 

 

 

5

ON

ON

 

 

 

5

OFF

OFF

 

 

 

5

OFF

ON

 

 

 

6

ON

OFF

 

 

 

6

ON

ON

6OFF OFF

6OFF ON

<Pneumatic specifications, 2 pedal sequence operation>

Operating mode

Memory switch setting

Work clamp operation After home position After sewing start detection

When

start

switch

is

Automatic lift

Automatic lift

depressed, work clamp drops

Dropped

 

sewing starts

 

 

 

 

 

 

 

Automatic lift

Lifts in

reverse

order

using

Dropped

work clamp switch

 

Dropped

 

 

 

 

 

 

 

 

 

 

 

 

 

Work clamp switch

 

Automatic lift

Automatic lift

 

 

 

Dropped

Left (right) work clamp

 

Right (left) work clamp

 

Automatic lift

Both work clamps lift

 

Dropped

 

 

Dropped

 

 

 

 

 

002

Work clamp drop sequence selection

0:Left and right simultaneously

1:Left Right

2:Right Left

Work clamp drop sequence selection

0:Left and right simultaneously

1:Left Right

2:Right Left

050

057

058

 

 

 

7

ON

OFF

 

 

 

7

ON

ON

 

 

 

7

OFF

OFF

 

 

 

7

OFF

ON

 

 

 

5

ON

OFF

 

 

 

5

ON

ON

5OFF OFF

5OFF ON

2-6. Stitch counter checking method

5058Q

1.While holding down the TEST key (1), press the <Pneumatic specifications, 2 pedal sequence operation> key

(2).

“Cnt” will be displayed in the PROGRAM No. display (3), and the cumulative number of stitches will be displayed in the menu display (4) in units of 100,000 stitches.

(While the 2-6. Stitch counter checking method key (5) is being pressed, the cumulative number of stitches will be displayed in units of 100 stitches in all 7 digits of the PROGRAM No. display and the menu display (4).)

2.When the TEST key (1) is pressed, the display will return to the normal display.

<Clearing the cumulative number of stitches>

1.When “Cnt” is displayed, press the <Clearing the cumulative number of stitches> key (6). The cumulative number of stitches will change to “0000” and the display will flash.

2.Press the RESET key (7) for two seconds or more. (The cumulative number of stitches “0000” will stop flashing and illuminate, and the setting will be cleared. )

3.When the TEST key (1) is pressed, the display will return to the normal display.