Operation panel settings

2. FUNCTION SETTINGS

Operation panel settings

No.

Setting

Setting items

Initial value

range

 

 

 

 

Operation panel changing limitation

 

 

0

No limits on changing setting values using the operation panel.

 

 

1

Program numbers, XY scale, sewing speed, lower thread counter, work clamp

 

 

height, intermittent height and digital tension values cannot be changed.

 

 

 

 

 

2

Program numbers, XY scale, sewing speed, work clamp height, intermittent height

 

350

and digital tension values cannot be changed.

0

 

 

3

Program numbers cannot be changed.

 

 

4

Program numbers and XY scale settings cannot be changed.

 

 

5

Program numbers, XY scale and sewing speed settings cannot be changed.

 

 

6

XY scale settings cannot be enlarged. (They can be reduced.)

 

 

7

Sewing speed setting cannot be changed.

 

351

Changing memory switches

OFF

OFF

Allowed

 

ON

Forbidden

 

 

Counting method for lower thread counter and production counter

 

352

0

Counted for each item of sewing data

0

1

Counted for each thread trimming operation.

 

 

 

2

Counted when sewing data ends or when split stops

 

353

Counter timing

for lower thread counter

OFF

OFF

Counted at the end of sewing.

 

ON

Counted at the start of sewing.

 

 

Switching program numbers using an external switch

 

354

0

Disabled

0

 

Program number is switched by means of the 5 bits of option input (EXIN6

 

1 9

EXIN10).

 

 

 

Applicable numbers are: Setting number = 3rd digit, last two digits can be 1 31.

 

 

Switches split

numbers using an external switch

 

355

OFF

Disabled

OFF

ON

Split number is switched by means of the 5 bits of option input (EXIN6 EXIN10).

 

 

 

Applicable numbers are 1 31 (only enabled for independent split mode)

 

 

 

 

User program settings

 

 

No.

Setting

Setting items

Initial value

range

 

 

 

 

Moving to start

point when switching user programs

 

450

OFF

Feed moves to the start point after starting and switching.

OFF

ON

Feed moves to the next sewing start point at the same time as the user program

 

 

 

switches.

 

 

 

 

452

Limitations on

changing settings for user programs

OFF

OFF

No limit

 

ON

User program contents cannot be changed.

 