Brother BAS-311G service manual Function Settings

Models: BAS-311G

1 152
Download 152 pages 29.81 Kb
Page 19
Image 19
Manual background

2. FUNCTION SETTINGS

No.

Setting

Setting items

Initial value

range

 

 

 

554

Thread breakage detector

OFF

OFF

Disabled

 

ON

Fiber-type thread breakage detector used

 

555

Thread breakage detector detection sensitivity

OFF

OFF

5 stitches at sewing start, 3 stitches while sewing

 

ON

10 stitches at sewing start, 3 stitches while sewing

 

 

Inner clamping

device (Option output No. 13)

 

 

0

Disabled

 

 

 

Inner clamping device is used.

 

556

1

(Retract operation is carried out at the sewing end to prevent interference with the

0

 

needle.)

 

2

Inner clamping device is used. (No retract operation at the sewing end.)

 

 

 

Inner clamping device operates for 1/4 of the sewing pattern and returns for the

 

 

3

other 3/4.

 

 

 

(No retract operation)

 

 

External wiper

device

 

557

0

Disabled

1

1

Solenoid-type wiper device is used.

 

 

 

2

Pneumatic-type wiper device is used. (Option output No. 2)

 

558

External error

monitoring input

OFF

OFF

Disabled

 

ON

Enabled (P10, option input No. 13 [AIRSW])

 

 

Operating indicator output

 

559

OFF

Disabled

OFF

 

Option output No. 9: Output ON while operating

 

ON

Option output No. 10: ON during lower thread conversion and during test mode

 

 

 

Option output No. 11: ON when error is generated

 

 

Automatic ejector (Option output No. 3 output, option input No. 1 = right sensor, input No. 2 = left

 

 

sensor) [Pneumatic specifications]

 

560

0

Disabled

0

1

Standard operation

 

 

 

2

Sewing starts when cassette sensor is ON

 

 

3

Start switch is enabled even if cassette sensor is OFF.

 

 

Timer from

sensor detection to sewing start when automatic ejector automatic starting is set

 

561

(memory switch No. 560 = 2) [Pneumatic specifications]

100

 

0 999

Time from after the cassette is chucked until automatic starting

 

 

Changes the

digital tension setting value.

 

562

OFF

Tension number can be changed regardless of the sewing data.

ON

ON

Only tension No. 0 and the tension numbers detected in the sewing data can be

 

 

 

changed.

 

 

 

 

563

2-step tension

is possible (When using spring-type main tension)

OFF

OFF

Disabled

 

ON

2-step tension is used.

 

 

Increases maximum tension release force when using a spring-type main tension

 

 

0

Disabled (Tension release is open at the sewing end.)

 

564

1

Increases the force (Tension release is closed at the sewing end. If tension release

0

is open, it will be closed in approximately 5 minutes.)

 

 

 

 

2

Increases force to the maximum. (Tension release is closed at the sewing end. If

 

 

tension release is open, it will be closed in approximately 1 minute.)

 

 

 

 

 

Thread nipper

device (*6)

 

565

OFF

Disabled

OFF

ON

Thread nipper device installed (Memory switch No. 500 must also be set to ON or

 

 

 

OFF.)

 

 

 

 

*6 Not used for the BAS-311G and BAS-326G.

 

12

BAS-311G, BAS-326G

Page 19
Image 19
Brother BAS-311G service manual Function Settings