8. ELECTRICAL MECHANISM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem #1 The power indicator does not illuminate when the power is turned on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cause

 

Inspection/Remedy/Adjustment

 

Replacement if a malfunction

 

3.

Malfunction of power cord

Disconnect connector P9 (ACIN) on the power

 

 

 

 

supply motor P.C. board from the circuit board,

 

 

 

 

turn on the power, and then measure the voltage

 

 

 

 

between pins 3-4 of the cord-side connector.

 

 

 

 

 

OK if same as wall outlet voltage

 

 

 

 

 

 

 

After inspecting, turn off the power and insert

 

 

 

 

connector P9.

 

 

 

 

 

 

 

 

 

4880Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Blown fuse

Remove fuses

F7 and

F8 and

check

the

Glass tube fuse

 

 

 

continuity.

 

 

 

 

 

 

15A-250V

 

 

 

OK if continuity

 

 

 

 

 

 

 

 

 

 

(If there is no continuity, replace the fuse and

 

 

 

 

then carry out the inspections in 5. )

 

 

 

 

 

5. Malfunction of power supply

Disconnect connector P17

 

(M-MOTOR) of the

Power supply motor P.C.

 

 

motor P.C. board

main P.C. board, turn on the power, and then

board

 

 

 

measure the voltages between the pins at the

 

 

 

 

cord-side connector.

 

 

 

 

 

 

 

 

 

OK if the voltages are as shown in the table

 

 

 

 

below.

 

 

 

 

 

 

 

 

 

 

 

Pin Nos.

 

Normal

 

 

 

 

 

 

 

+ side

side

 

voltage

 

 

 

 

 

 

 

1

3

 

+5V

 

 

 

 

 

 

 

2

4

 

+5V

 

 

 

 

 

 

 

6

5

 

+24V

 

 

 

 

 

 

 

7

5

 

+24V

 

 

 

 

 

 

After measuring, turn off the power, wait 5

 

 

 

 

minutes or more and then insert P14.

 

 

 

 

 

 

5085Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

Malfunction of main P.C. board

With connector

P17 (M-MOTOR) inserted

into

Main P.C. board

 

 

 

the main P.C. board, turn on the power and then

 

 

 

 

measure the voltages between the pins at the

 

 

 

 

cord-side connector.

 

 

 

 

 

 

 

 

 

OK if the voltages are as shown in the table

 

 

 

 

below.

 

 

 

 

 

 

 

 

 

 

 

Pin Nos.

 

Normal

 

 

 

 

 

 

 

+ side

side

 

voltage

 

 

 

 

 

 

 

1

3

 

+5V

 

 

 

 

 

 

 

2

4

 

+5V

 

 

 

 

 

 

 

6

5

 

+24V

 

 

 

 

 

 

 

7

5

 

+24V

 

 

 

 

 

 

After measuring, turn off the power.

 

 

 

 

 

 

5085Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

Malfunction of panel P.C. board

Check that connector P1

(PANEL)

is inserted

Panel P.C. board

 

 

 

into the main P.C. board,

 

and that

connector

Panel harness

 

 

 

CN2 (MAIN) is inserted into the panel P.C.

 

 

 

 

board.

 

 

 

 

 

 

 

BAS-311G, BAS-326G