3. INSTALLATION

(10)

(21)

(20)

Lock the cord

clamp at the top.

(13)

(12)

1176S

13.Securely connect connectors P1 to P7, P14, P18, P23 and P26 as indicated in table below.

Note

Check that the connector is facing the correct way, and then insert it firmly until it locks into place. Furthermore, lock the cord clamp at the top.

Machine head connectors

 

Connection location on

Cord clamps used

Connection location

No. of pins

Cord mark

circuit board

 

X, Y, Sewing sensor

12-pin

[1]

P1

(ORG)

None

Synchronizer

5-pin

[2]

P2

(SYNCHRO)

F

EMERGENCY STOP switch

9-pin

[3]

P3

(HEAD)

None

Solenoid valve

12-pin

[4]

P4

(VALVE)

None

(for pneumatic)

 

 

 

 

 

Solenoid

 

 

 

 

F, G

Presser foot

8-pin

[5]

P5

(SOL)

Thread trimmer

 

 

 

 

 

 

Wiper

 

 

 

 

 

Pulse motor, Y

5-pin

[6]

P6 (YPM)

F,G

Pulse motor, X

5-pin

[7]

P7

(XPM)

F, G

(blue)

 

 

 

 

 

Upper shaft motor

3-pin

None

P14 (UVM)

A, B, C, D, E

Operation panel

10-pin

[M]

P18 (PANEL)

A, B

Head position switch

3-pin

[23]

P23 (IMSW)

A, B

 

 

 

 

 

 

Machine specification select

10-pin

[26]

P26 (SELECT)

None

connector

 

 

 

 

 

14.Secure the cord bundle (10) with the cord clamp (20).

Note

Check that the cords do not get pulled when the machine head is tilted back gently.

15.Close the cord presser plate (15) in the direction of the black arrow, and secure it by tightening the screws (14).

16.Install the control box cover (main P.C. board mounting plate (13)) with the six screws (12).

Note

Check that the cords do not come into contact with the fan (21) and that they are not clamped by the cover at this time.