3. INSTALLATION

3-10. Connecting the ground wire

CAUTION

Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a serious electric shock.

Red

 

3-

phase

 

 

 

White

 

power supply

 

Black

 

Yellow/Green

Yellow/Green

Connect to

 

 

 

 

ground

 

 

 

 

0064Q

 

 

 

 

 

Connection method for 3-phase power supply

3-11. Connecting the cords (Installing the operation panel)

(4)

(8)(3)

(1)

(9)

(2)

1 mm

40 mm

(7)

(6)

(5)

Front cover

1.Assemble the operation panel stand (1) and cushion A

(2).Then insert the bolts (4) together with the washers

(3)into the three holes from above, and then tighten

the nuts (5), washers (6) and cushion B (7) from below to secure the assembly.

Note

Tighten until the thickness of cushion B (7) becomes about 1 mm.

2.Pass the cords of the control panel assembly through the hole in the operation panel stand (1).

3.Attach the rubber sheet (8) to the hole in the operation panel stand (1) and then secure it with the bolt (9).

4.Insert the cord into the control box through the hole at the side of the box. Refer to page 13.

5.Secure the cord with the staples ( in two places).

Note

When opening the front cover, check that the code does not touch it.