9.STANDARD ADJUSTMENTS

9-10-3. BAS-326F-0

1268S

 

 

 

(3)

 

(3)

 

 

 

 

 

 

(2)

(4)

(2)

(4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5)

 

 

 

(5)

 

 

 

 

 

 

20 mm

Scale

 

 

 

 

 

 

(1)

 

 

 

 

1304S

 

1269S

 

 

1270S

1.Turn on the air, and then press the presser lifter switch (1) to raise the presser foot (2) .

2.Loosen the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4).

3.Place a scale against the presser foot (2), and then move presser lifter lever UR (3) and presser lifter lever UL (4) up and down to adjust so that the amount of presser lift is 20 mm from the top of the needle plate.

4.After adjusting the lift amount (20 mm), tighten the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4).

9-10-4. Adjusting the air pressure

(2)(4)

1.Air pressure should be 0.5 MPa.

The air pressure can be adjusted by pulling up and turning the control knob (2) on the integrator (1).

After adjustment is complete, push the control knob (2) downward to lock it.

2.If water stands in the bottle of the integrator (1), turn the drain cock (3) in the direction indicated by an arrow

to drain the water.

Note

Open the air cock (4) slowly.

(1)

(3)

1271S

50

BAS-311F-0, 311F-L, 326F-0

Page 57
Image 57