12. ERROR CODES

 

 

 

 

 

 

 

 

 

Code

Cause

Remedy

 

 

 

 

E.A0

Start switch was pressed when there was no

Read sewing data again.

 

 

sewing available data.

 

 

E.A1

Can not detect home position. X-Y feed or

Turn off power and, check X-Y feed and connector P1.

 

connection of home position sensor is incorrect.

 

 

 

 

 

 

E.c0

Motor PROM is not correctly inserted.

Turn off power and check it.

 

E.c1

Cooling fan (left one when viewed from front) in

Turn off power and check it.

Check fan connector.

 

control box does not operate.

 

 

E.c2

Heat-sink on main PCB is overheating.

Turn off power and clean air inlet port.

E.c3

Overcurrent was detected in X pulse motor.

Turn off power and check it.

 

E.c4

Overcurrent was detected in Y pulse motor.

Turn off power and check it.

 

E.c5

Cooling fan (right one when viewed from front) in

Turn off power and check it.

Check fan connector.

 

control box does not operate.

 

 

 

 

 

E.d0

Air pressure has dropped.

If not use detector, set OFF memory switch 1d.

 

 

 

 

E.E0

Control PROM is not correctly inserted.

Turn off power and check it.

 

E.E1

Main PCB detected communication error.

Turn off power and then on again.

E.E2

Panel PCB detected communication error.

Turn off power and then on again.

E.E3

Incorrect connection of cable between operation

Turn off power and check it.

 

 

panel and control box.

 

 

 

 

 

 

E.F0

Solenoid is short-circuited (malfunction of main

Turn off power and check it.

 

 

circuit board) or power supply relay is not operating

 

 

 

(malfunction of power supply circuit board).

 

 

E.F1

Incorrect connection of cable between power supply

Turn off power and check connector P20.

 

PCB and main PCB.

 

 

E.F2

Over current at power supply PCB.

Turn off power and check it.

 

 

 

 

 

REFERENCE segment LED alphabet

Panel display

Text display

 

A

 

B

 

C

 

D

 

E

 

F

 

6

 

H

 

L

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAS-311F-0, 311F-L, 326F-0

65

Page 72
Image 72